Dynisco丹尼斯科1380-2-3压力指示器
价格:1.00
地区:上海市
电 话:021-37635502
手 机:13661817191

Benefits Description Features 1380-X-X ? Dire pressure readings ? Easy to use ? Store and download saved configurations ? Analog retranission ? Send and receive information from PLC’s, PC’s, etc. ? Recall extremes of the process ? Save panel space ? 350 Ohm strain gage input ? Push-button programming and calibration ? DynaLink software configurable ? Scalable, voltage or current models ? MODBus communications option ? Peak and valley deteion ? Convenient 1/8 DIN size Dynisco’s 1380 strain gage indicator offers a field seleable display and dual configurable alarms to meet your changing pressure indication requirements. The available mA or Vdc linear retranission or serial communications enable the user to log, send and/or retrieve process information. A simple front panel instrument calibration and compa profile make the 1380 the ideal indicator for your process. The indicator comes equipped with beacons which display the alarms, remote configuration and the desire pressure unit, and has a cable hook up that allows use of DynaLink, the 1380 indicator configuration software.

PERFORMANCE CHARAERISTICS Instrument te: Microprocessor based indicating panel meter Display: 5 LED dis 0.5” (13.2 mm) high; 2 red LEDs for alarm indication; 1 green LEDs for remote configuration Termination: Screw terminals on rear with safety covers Dimensions: 1/8 DIN, 1.89” H x 3.78” W x 4.13” D (48 mm H x 96 mm W x 105 mm D) Front Panel: IP65/NEMA4 rated with gasket Accuracy: +/-0.1% of full scale with shunt cal rmal Mode Rejeion Ratio: 60 dB at 50/60 Hz Sampling Time: 100 mS Operating Temperatures: 32oF to 130oF (0oC to 55oC) ELERICAL CHARAERISTICS Input: One 350 Ohm strain gage bridge sensor Bridge Excitation: 10 Vdc +/- 7% Sensitivity: 1.4 to 4 mV/V, automatically sensed Input Power: 85 - 264 Vac (24 Vdc available) Calibration: With shunt resistor or applied pressure Shunt Calibration Range: From 40% to 100% Display: Keyboard configurable from 10 to 99,900 Resolution: 1 di with range to 2,010; 10 di with range to 20,100; 100 di with range to 99,900Zero Balance: +/-25% full scale Open Input Proteion: Displays OPEn if any of the four or six sensor wires are open ALARMS Alarm Te: High/low setpoints; Dire/reverse aing; Automatic or manual reset; Masking available Alarm Output: Two SPST, or NC Conta Rating: 0.6A @ 110 Vdc, 0.5A @ 220 Vdc, 0.3A @ 110 Vdc ANALOG RETRANISSION OUTPUTS Output: 0 - 20 mA, 4 - 20 mA - max 500 ohms 0 - 5 Vdc, 0 - 10 Vdc - min 5000 ohms Scaling: Output is scalable from 0 - 99,900 Output Resolution: +/-0.05% of output span maximum Accuracy: +/-0.2% of span