进口传感器校验Z6FD1
价格:电议
地区:上海市

· 德国HBM称重传感器Z6FD1

Z6FD1 称重传感器 悬臂梁式
- 量程:5,10,20,50,100,200,500,1000 kg - : D1,C3,C4,C6 OIML ;
- 用途:平台秤,包装秤, , 皮带秤,容器秤,配料秤 … ;广泛应用的一款传感器。

 

Technical data

Type

Z6FD1

Z6FC3

Z6FC4

Z6FC6

Accuracy class according to OIML R 60

Maximal numbers of load cell verif. intervals (nLC)

D1

1000

C3

3000

C4

4000

C6

6000

Max. capacity (Emax)

kg

 

 

 

t

5; 10; 20; 50;

100; 200;

 

500

 

1

10; 20; 50;

100; 200;

 

500

 

1

20; 50; 100;

200;

 

500

50; 100; 200; 

Minimum load cell verification interval (vmin)

Sensitivity (Cn)

Tolerance on sensitivity

Temperature effect on sensitivity (TKC)1)

 

Temperature effect on zero balance (TK0)

 

Hysteresis error (dhy)1)

(dlin)1)

Creep (dDR) in 30 min. 

Input resistance (RLC) (black -blue) 

Output resistance (R0) (red -white) 

Reference excitation voltage (Uref)

Nominal range of excitation voltage (BU)

Insulation resistance (Ris)

Nominal temperature range (BT)

Service temperature range (Btu)

Storage temperature range (Btl)

% of Cn

mV/V

 

%

 

% of 

Cn/10K

% of 

Cn/10K

%

 

%

 

%

 

?

 

?

 

V

 

V

 

G?

oC [oF]

oC [oF]

oC [oF]

0.0360

0.0090

0.0066

2

 

< +1;  - 0.1 < +0.05

 

< +0.0500 < +0.0080 < +0.0070 < +0.0040

 

< +0.0500 < +0.0125 < +0.0093 < +0.0093

 

< +0.0500 < +0.0170 < +0.0130 < +0.0080

 

< +0.0500 < +0.0180 < +0.0150 < +0.0110

 

< +0.0490 < +0.0166 < +0.0125 < +0.0083

 

350  - 480

 

356 + 0.2 356 + 0.12

 

5

 

0.5...12

 

>5

 

-10...+40 [15...+105]

-30...+70 [ -20...+160]

-50...+85 [ 60...+185]

Safe load limit (EL)

Breaking load (Ed)

% of Emax

% of Emax

150

300

Max. capacity

Permissible dynamic load (Fsrel)

(vibration amplitude according to DIN 50100)

Deflection at max. load, (snom) approx. (±15%)

Weight (G), approx.

kg

% of Emax

 

mm

kg

5

100

 

0.24

0.5

10

100

 

0.3

0.5

20

100

 

0.29

0.5

50

100

 

0.27

0.5

100

100

 

0.31

0.5

200

100

 

0.39

0.5

500

70

 

0.6

0.5

1000

100

 

0.55

2.3

Protection class (IP) acc. to EN60529 (IEC529)


IP 67   (more rigorous test conditions: 100hat 1m Water column)

Material Measuring body Metal below Cable entrance Cable sheath


 

stainless steel stainless steel

stainless steel / Neoprene

PVC

Optionally


Explosion proof version (EEx ib IIC T4) PTB-no. EX-90.C.2094











 

1)     The data for deviation of linearity, hysteresis and temperature effect on sensitivity are typical values. The sum of these data meets the

requirements according to OIML R60. 

 


测量范围

0-1T

测量精度

D1,C3

响应时间

0.5

输入电压

5V

防护等级

IP65]