回收横河AQ6376收购Yokogawa AQ6376光谱仪


深圳市华盛电子仪器有限公司长期销售、回收、租赁、维修、计量高频全新/二手仪器!!欢迎来电咨询

主营品牌;安捷伦、美国泰克美国福禄克、艾法斯、日本菊水、北京普源、台湾固纬、德国惠美、美国吉时利、美国力科、德国罗德与施瓦茨、英国马可尼、英国施伦伯杰、日本安立、日本爱德万等国际品牌仪器

回收/销售产品;手机综合测试仪、蓝牙测试仪、网络分析仪、频谱分析仪、信号源信号发生器、示波器、功率计、频率计、误码仪、LCR电桥、电源、数据采集仪、噪声系数分析仪、多用表校准仪、万用表、天馈线测试仪安立、温度记录仪、逻辑分析仪、红外热像仪、色彩分析仪、阻抗测试治具及附件、衰减器 、熔纤机 等等

深圳市华盛电子仪器有限公司是一家长期高价回收仪器仪表,长期供应全新/二手仪器设备的企业有限公司,公司一直以诚信,公平,公正与现金的结算的方式运作。提供上门提货或物流公司代收款的操作模式高价收购国内外仪器仪表设备让您与您公司的闲置,废弃,待处理的设备快速的资金回笼。

AQ63761.jpg

MWIR WAVELENGTH with internal gas purge and cut filter

The AQ6376 is the latest version of our bench-top optical spectrum analyzer extending the wavelength coverage well beyond the NIR range of our previous models into the MWIR region from 1500 to 3400 nm.

Popular applications include the detection of gases such as carbon oxides (COx), nitrogen oxides (NOx), and hydrocarbon gas (CxHy) for environmental studies.

Similar to the long wavelength model, it offers the added benefits of gas purging input ports / output ports, a built-in cut filter for high order diffracted light, and a novel double speed mode which increases the sweep speed up to 2 times compared to the standard sweep mode.

Key feature summary

  • Long wavelength range: 1500 to 3400 nm

  • Gas purging ports to reduce water vapor effects

  • Built-In cut filter for high order diffracted light

  • Double Speed Mode to further enhance fast measurement speed

  • High sensitivity down to -65 dBm

  • High resolution to 0.10 nm

  • Wide close-in dynamic range (55dB)

  • Fast auto-calibration

  • Free space optical input for maximum flexibility, low maintenance, and high reliability  

  • Applicable to single-mode and multimode fibers

  • Excellent performance for environmental gas sensing Laser Spectroscopy 

  • Indispensable tool for R&D and manufacturing of optical devices in the wavelength range from telecom band to 3.4μm 

New Features

Purge feature

Due to the high resolution and sensitivity of the AQ6376, it can actually detect the presence of water molecules in the air. The water vapor is detected in the upper Near-IR wavelength region and could overlap with or mask the spectral characteristics of the actual device under test in that particular region.

By continuously supplying a pure purge gas such as nitrogen to the monochromator through the ports on the back panel, the AQ6376 can reduce the influence of water vapor absorptions and provide more reliable and accurate measurements than ever before.

Built-in cut filter for high order diffracted light

Due to the diffractive technology used, the monochromator in some circumstances could generate high order diffracted light, which appears at wavelengths equal to the integral multiple of input wavelengths.

By cutting incoming light below 1500 nm with the built-in filter, the AQ6376 drastically reduces the influence of high order diffracted light on the measurement. Thus, the measured data are always reliable and replicate the real signal under test.

Double speed mode

Increases the sweep speed up to 2 times compared to the standard sweep mode, with only a 2 dB penalty to the standard sensitivity value.

Long Wavelength Range: from 1500nm to 3400nm

The AQ6376 covers not only the wavelength span used in communications, but also the 3μm region which is used for environmental sensing, medical, biology and industrial applications.

High Sensitivity: down to -65dBm

The AQ6376 can measure optical power from +13dBm down to -65dBm thanks to its high-dynamic and very low noise components and circuits used for photo detection. This enables precise measurements of both high power and low power sources.

Measurement sensitivity can be chosen among 7 values according to the measurement speed required by the specific test to be performed.


The spectrum of a white light source (yellow) and the background noise of AQ6376 (purple) 

High Resolution & Wide Dynamic Range

The AQ6376 uses a double-pass monochromator structure to achieve high wavelength resolution (0.10 nm) and wide close-in dynamic range (55 dB). Thus, closely allocated signals and noise can be separately measured.


Measured 1550 nm laser, Close-in Dynamic range: @ peak±2 nm

High speed Measurement

GREATER EFFICIENCY 

High Speed Sweep

With a proprietary sweep technique the AQ6376 achieves a much faster sweep speed than conventional measurement systems, which use a monochromator. Max. sweep time is only 0.5 sec. for 100 nm span.

Fast command processing and data transfer

Applying a fast microprocessor, the AQ6376 achieves very fast command processing speed and Ethernet interface provides up to 100 times faster data transfer speed than GP-IB.

Fast auto-calibration

The AQ6376 has a built-in reference light source for wavelength calibration and optical alignment of the monochromator components, allowing it to deliver always-accurate measurements. 
The calibration and alignment process takes less on the unit take than 2 minutes and is fully automatic. 
NOTE: The wavelength calibration can also be performed by using an external reference source.

Free-Space Optical Input

The AQ6376 uses a free-space optical input structure, i.e. no fiber is mounted inside the instrument.

This smart solution is:

  • WORRY-FREE, as no internal fiber can be scratched or get dirty

  • MAINTENANCE-FREE, as no internal fiber has to be cleaned

  • VERSATILE, as the instrument accepts both /PC and /APC connectors

  • DUAL PURPOSE, as the instrument accepts both Single-Mode and Multi-Mode fibers without being affected by the high insertion loss from MM-SM fibers matching