防意外接触规(防触电)Protection against accidental contact during insertion (IEC 7006-55-2)

undefined

The gauge is shown in the test position. In the rest position, the plunger shall be above plane V.

图中所示量规柱塞处于检验状态。当柱塞处于静止状态时,W面应比V面缩进更深些。


 E14-7006-55-2防触电接触规

 

Reference

尺寸符号

Dimension

尺寸(mm)

Tolerance

公差(mm)

Reference

尺寸符号

Dimension

尺寸(mm)

Tolerance

公差(mm)

D

13.97

+0.0/-0.02

Q

15

±0.1

F

18.1

+0.05/-0.0

R

Approx.近似12.5

G

19

+0.02/-0.0

U

8

±0.1

H

7.5

±0.1

r

<0.5

M

27.5

±0.1

r1

2.5

+0.5/-0.0

N

28.5

+0.0/-0.02

α

35°

±30

P

10

±0.1




 

 

Purpose目的:

 

To check protection againstaccidental contact during insertion of caps E14 on finished lamps.

 

检验成品灯上E14灯头在插入时防止意外接触性能。

 

 


E14-7006-55-2防触电接触规 

Testing测试方法:

 

 The shape of the lamp with regard to protection againstaccidental contact is assumed to be correct if, when the lamp is pushed as far as possible into the gauge, surface W does not protrude beyond surface V. The application of this gauge is restricted to the following lamps when they are fitted with E14 caps, in accordance with sheet 7004-23: candle lamps/round bulb lamps/domestic tubular lamps/pygmy lamps.

 

如果灯头完全插入量规时,W面没有凸出V面,则可认为灯的防意外接触性能是合格的。此量规仅适用检验装有符合IEC7004-23中所示的E14灯头的烛形灯,球形灯,家用管形灯和小型灯。