Operation
Remove the battery compartment and panel and check that a good quality PP3
alkaline battery has been fitted. Hold the checker away form any surface and press
the test button, the insulative red LED light.
Place the checker onto the surface that requires testing, again press the test button
and hold. The LED that illuminates constantly is the decade measured.
10/3=1 kilohm Green LED 10/9 = 1,000 meg ohms Yellow LED
10/4=10kilohms Green LED 10/10=10,000megohms Yellow LED
10/5=100kilohms Green LED 10/11=100,000megohms Yellow LED
10/6=1megohm Yellow LED 10/12=1,000,000megohms Red LED
10/7=10megohms Yellow LED >10/12=Insulative Red LED
10/8=100megohms Yellow LED
Checking Resistance to ground
Insert the ground/earth leakage lead into the ground/earth leakage socket. This is
lates the test probe ont the right side of the meter. (The same blue as the socket).
Connect the croc clip to your ground connection.
Place the checker on to the surface to be tested, press and hold the test button. The
LED that illuminates constantly is the decade measured. The
Measurement will be resistance to ground in ohms instead of ohms per square.