用于管材检测的MultiScan MS5800涡流检测仪
价格:电议
地区:
电 话:86-010-57727576
手 机:18901052321
传 真:86-010-58126636
产品品牌:
Olympus NDT-R/D tech
产品型号:
MultiScan MS 5800

MultiScan MS 5800 for Tube Inspection

Multi-technology system that offers eddy current, magnetic flux leakage, remote filed and IRIS ultrasound technologies.

The MultiScan MS5800 is a multi-technology system offering these technologies:

  • Eddy Current
  • Magnetic Flux Leakage
  • Remote Field
  • IRIS Ultrasound
  • Tube Inspection with Eddy Current Testing (ECT)
  • Tube Inspection with Internal Rotating Inspection System (IRIS) for Ferrous and Nonferrous Materials
  • Tube Inspection with Remote Field Testing (RFT)
  • Tube Inspection with Near Field Testing (NFT)
  • Tube Inspection with Magnetic Flux Leakage (MFL)

MS 5800E 
Tube Inspection with Eddy Current Testing (ECT)

  • Condensers
  • Feedwater heaters
  • Heat exchangers
  • Air conditioners

Eddy current testing is a noncontact method used to inspect nonferromagnetic tubing. This technique is suitable for detecting and sizing metal discontinuities such as corrosion, erosion, wear, pitting, baffle cuts, wall loss, and cracks in nonferrous materials.

  • Two coils are excited with an electrical current, producing a magnetic field around them. The magnetic fields penetrate the tube material and generate opposing alternating currents in the material. These currents are called eddy currents.
  • Any defects that change the eddy current flow also change the impedance of the coils in the probe.
  • These changes in the impedance of the coils are measured and used to detect defects in the tube.

MultiScan MS 5800E Key Features

  • 4 simultaneous frequencies per input. 
    This feature allows inspection speeds up to 2 m/s with 4 frequencies on absolute and differential channels, without signal distortion.
  • Electronic probe balancing. 
    No separate external reference probe is required for absolute channel operation.
  • 4 ECT inputs and up to 64 multiplexed channels. 
    The MultiScan™ MS 5800E can support a large number of ECT channels to perform array probe inspections. Compared to single-channel inspection, the array probe technology allows faster and easier surface coverage.

MS 5800U 
Tube Inspection with Internal Rotating Inspection System (IRIS) for Ferrous and Nonferrous Materials

  • Boilers
  • Feedwater heaters
  • Air coolers
  • Heat exchangers

The ultrasonic IRIS option is used to inspect a wide range of materials including ferrous, nonferrous, and nonmetallic tubing. This technique detects and sizes wall loss resulting from corrosion, erosion, wear, pitting, cracking, and baffle cuts. Olympus digital IRIS inspection technology is used extensively as a prove-up technique for remote field testing, magnetic flux leakage, and eddy current inspections. 

MultiScan MS 5800U (IRIS) Key Features

  • Setup wizard 
    Simplifies equipment calibration for different tube diameters and materials. The wizard also generates the reporting code for the inspection.
  • Real-time gain and gate controls 
    UT settings can be modified during the C‑scan acquisition to quickly optimize signal detection.
  • Real-time and continuous color C-scans 
    Reduces missed flaws with C-scan displays. Enhance the quality and appearance of your reports by including color maps and cross-section views of defects.
  • Full tube-length recording 
    Used to analyze data offline and assess results with the customer.

MS 5800R 
Tube Inspection with Remote Field Testing (RFT)

  • Boilers
  • Feedwater heaters
  • Carbon steel heat exchangers

Remote field testing (RFT) is being used to successfully inspect ferromagnetic tubing such as carbon steel or ferritic stainless steel. This technology offers good sensitivity when detecting and measuring volumetric defects resulting from erosion, corrosion, wear, and baffle cuts.

Olympus remote field probes and the MultiScan™ MS 5800 are used to successfully inspect heat exchangers, feedwater heaters, and boiler tubes, around the world.

Tube Inspection with Near Field Testing (NFT)

  • Air coolers
  • Carbon steel heat exchangers

The near field testing (NFT) technology is a rapid and inexpensive solution intended specifically for fin-fan carbon-steel tubing inspection. This new technology relies on a simple driver-pickup eddy current probe design providing very simple signal analysis.

NFT is specifically suited for the detection of internal corrosion, erosion, or pitting on the inside of carbon steel tubing. The NFT probes measure lift-off or "fill factor" and convert it to amplitude-based signals (no phase analysis). Because the eddy current penetration is limited to the inner surface of the tube, NFT probes are not affected by the fin geometry on the outside of the tubes.

Tube Inspection with Magnetic Flux Leakage (MFL)

  • Feedwater heaters
  • Air coolers
  • Carbon steel heat exchangers

Magnetic flux leakage (MFL) is a fast inspection technique, suitable for measuring wall loss and detecting sharp defects such as pitting, grooving, and circumferential cracks. MFL is effective for aluminum-finned carbon steel tubes because the magnetic field is almost completely unaffected by the presence of such fins.

MultiScan MS 5800R Key Features (RFT)

  • RFT with up to four different frequencies and real-time mixes.This feature allows more flexibility for mixing and defect validation. The detection and sizing of flaws at the support plate becomes easier with multifrequency inspections and dual-driver operations.
  • RFT with frequencies ranging from 20 Hz to 250 kHz. 
    The high frequency available with the MultiScan MS 5800R™ extends the RFT inspection to thin materials with low permeability, such as the stainless steel 400 series and other ferromagnetic alloys.
General
Power120 VAC or 220 VAC ±10%, automatic selection, 48 Hz to 63 Hz
Size (excluding handle)45 cm x 30 cm x 22 cm
WeightMaximum weight with all modules installed: 12.8 kg
Environment-20°C to 45°C operating ambient, -20°C to 70°C storage; 95% relative humidity, noncondensing
Computer interface100Base-T Fast Ethernet
Eddy current testing
Probe inputs4 independent differential inputs and up to 64 multiplexed inputs (16 time slots)
ECT channels16 simultaneously (4 inputs x 4 frequencies) 
256 in super-multiplexed mode (with 16 time slots)
Number of frequenciesUp to 8 frequencies
Frequency rangeAdjustable from 20 Hz to 6 MHz
Acquisition rate40 kHz per channel (in conventional mode) 
14 kHz divided by the number of time slots (in multiplexed mode or MFL)
Supported probesUniversal connector supports all standard differential and absolute bobbin, impedance, transmit-receive, and rotating probes 
(Adaptor cable might be required.)
Probe balancingTrue electronic probe balancing. No separate external reference probe is required for absolute channels.
Output voltage20 Vp-p per generator (2 outputs)
Output current1 A (peak)
Real-time alarms8 independent alarms
Encoders2 quadrature encoders and digital inputs
Remote field testing, near field, and magnetic flux leakage
Probe inputs4 independent inputs for RFT/NFT 
4 independent inputs for MFL
RFT/NFT channels16 simultaneously (4 inputs x 4 frequencies)
MFL channels4 simultaneously 
64 in multiplexed mode 
(4 inputs x 16 time slots)
Number of frequenciesUp to 4 frequencies
Frequency rangeAdjustable from 20 Hz to 250 kHz
Acquisition rate40 kHz per channel (in conventional mode) 
14 kHz divided by the number of time slots (in multiplexed mode)
Supported probesSupports any differential and absolute probes with single exciter, dual exciters, dual pickup, near field, and magnetic flux leakage (Adaptor cable might be required.)
Probe balancingTrue electronic probe balancing
Output voltage20 Vp-p per generator (2 outputs)
Output current1 A (peak)
Analog outputX and Y components of the first input
Real-time alarms8 independent alarms
Encoders2 quadrature encoders or digital inputs
Ultrasonic IRIS testing
Number of pulsers/receivers1 channel in pulse-echo mode
System bandwidth0.5 MHz to 25 MHz
Sampling rate8 bit 100 MHz
Transducer frequencies1 MHz to 20 MHz
Pulse repetition rateUp to 20 kHz
Dynamic gain (linear amplifier)70 dB, 1 dB steps
A-scan length32 to 8,092 points
Pulse voltage50 V to 300 V, 1 V steps
High-pass filterNone, 2, 5, 10 (MHz)
Data-acquisition synchronizationTime, continuous, position, or external
Encoders2 quadrature encoders and digital inputs (requires MultiView 6.1 or higher)
Hardware options (factory configurable)
5800-EEddy current capability
5800-RRemote field, near field, and magnetic flux leakage capability
5800-1U1 UT channel (IRIS)