美国 Magna Power XR系列 可编程直流电源 2KW,2U机箱
价格:电议
地区:
电 话:86 021 61911916
手 机:13671590819
传 真:86 021 61911916
主要特点功率密度面世:可编程8KW 嵌 2U机箱宽输出电压、电流范围:0-16 Vdc to 0-1000 Vdc 和 0-2 Adc to 0-375 Adc以标准的宽输入电压、频率范围:从 208 Vac 到 480 Vac 、频率50 Hz 到 400 Hz全支持风冷随负载智能而变:闲置模式风冷智能关闭高的可编程和监测:± 0.075%&± 0.2%高效率:高达88%满载I/O标准通讯接口:37针电路标准的光隔离的用户I / O界面,无需额外的隔离电路高效率的运作:高达92%的效率在满载情况下RS232接口标配(标准SCPI命令):
GPIB,USB,以太网,RS485接口可选可选以太网LAN接口(LXI-certified Ethernet communications:内嵌web-server过压过流保护关闭标准(OCT&OVT STD): 过压保护和过流保护机械接触器高速断开主输入可回馈电网选件(MT series):电能可回馈(Power Cycle AC Grid),自动谐波消除平衡系统,产生(6n±1)-12/18/24/48个脉冲的回馈电网技术IIII驱动程序:多种可视化编程应用可支持Labview,Labwindows/CVI,IVI驱动等可编程输出模组:具有数字键盘仿真自定义电源文件自动变向控制技术:电流和电压交越转换前面板计量校准:界面简洁、显示清晰 

Specifications

 

Input
Nominal Voltage
3 phase, 3 wire + ground
208 VAC (operating range 187 - 229 VAC)
240 VAC (operating range 216 - 264 VAC)
380 VAC (operating range 342 - 418 VAC)
415 VAC (operating range 373 - 456 VAC)
440 VAC (operating range 396 - 484 VAC)
480 VAC (operating range 432 - 528 VAC)
1 phase, 2 wire + ground
(2 kW models only)
208 VAC (operating range 187 - 229 VAC)
240 VAC (operating range 216 - 264 VAC)
Frequency50 Hz through 400 Hz
Power FactorGreater than 92% at maximum power
Environmental
Operating Temperature0°C to 50°C
Storage Temperature-25°C to +85°C
Temperature Coefficient0.04 / °C of maximum output current
Air CoolingSide air inlet, rear exhaust
Physical
PowerInput PhasesSize (H" x D" x W")Rack UnitsWeight
2 kW
4 kW
6 kW
8 kW



3.50" x 24" x 19" (8.89 x 60.96 x 48.26 cm)
3.50" x 24" x 19" (8.89 x 60.96 x 48.26 cm)
3.50" x 24" x 19" (8.89 x 60.96 x 48.26 cm)
3.50" x 24" x 19" (8.89 x 60.96 x 48.26 cm)
2U
2U
2U
2U
45 lbs (20.41 kg)
47 lbs (21.32 kg)
48 lbs (21.77 kg)
48 lbs (21.77 kg)
2 kW3.50" x 24" x 19" (8.89 x 60.96 x 48.26 cm)2U45 lbs (20.41 kg)
Output
RippleSee Model Charts
Line RegulationVoltage Mode: ± 0.004% of full scale
Current Mode: ± 0.02% of full scale
Load RegulationVoltage Mode: ± 0.01% of full scale
Current Mode: ± 0.04% of full scale
Load Transient Response2 ms to recover within ±1% of regulated output with a 50% to 100% or 100% to 50% step load change
Efficiency≥ 86% (See Model Charts)
Stability± 0.10% for 8 hrs. after 30 min. warmup
Maximum Slew RateStandard Models:
100 ms for an output voltage change from 0 to 63%,
100 ms for an output current change from 0 to 63%.
With High Slew Rate Option (+HS):
4 ms for an output voltage change from 0 to 63%,
8 ms for an output current change from 0 to 63%.
BandwidthStandard Models:
3 Hz with remote analog voltage programming,
2 Hz with remote analog current programming.
With High Slew Rate Option (+HS):
60 Hz with remote analog voltage programming,
45 Hz with remote analog current programming.
IsolationMaximum input voltage to ground: ±2500 Vac
Maximum output voltage to ground: ±1000 Vdc
User inputs and outputs: referenced to Earth ground
Programming Levels and Accuracy of Full Scale
 Voltage
Set Point
Current
Set Point
OVT
Set Point
OCT
Set Point
Remote Analog Programming Accuracy± 0.075%± 0.075%± 0.075%± 0.075%
Digital Programming Accuracy± 0.075%± 0.075%± 0.075%± 0.075%
Remote Analog Programming Levels0 - 10.0 Vdc0 - 10.0 Vdc0 - 10.0 Vdc0 - 10.0 Vdc
Monitoring Levels and Accuracy of Full Scale
 Output VoltageOutput Current
Remote Analog Monitoring Accuracy± 0.2%± 0.2%
Digital Monitoring Accuracy± 0.2%± 0.2%
Remote Analog Monitoring Levels0 - 10.0 V0 - 10.0 V
Control Limits
Remote Sense Limits3% maximum voltage drop from output to load
Period Programming LimitsMinimum period: 10 msec
Maximum Period: 9997 sec or 2.77 hours
Digital control inputs and outputs limitsInput voltage: 0 to 5 Vdc, 10K input impedance;
Output voltage: 0 to 5 Vdc, 5 mA drive capacity
5 V supply: 25 mA.