台湾华仪7611泄漏电流测试仪
价格:电议
地区:台湾
电 话:86 059 22297902
手 机:886987866158
传 真:86 059 22297901
类型泄漏电流测试仪品牌台湾华仪型号7611测量范围泄漏电流测试仪测量泄漏电流测试仪功率泄漏电流测试仪(KW)频率泄漏电流测试仪(HZ)重量泄漏电流测试仪(kg)尺寸泄漏电流测试仪(mm)电源泄漏电流测试仪 产品特点:内置微处理器,数值精准,操作简易完全符合安全标准的规范内建常见标准的人体仿真阻抗,一组外接,使用效率高可量测常态、单一故障及接地失效的泄漏电流可以和华仪耐压测试器结合使用,组成自动化测试系统量测频宽达1MHZ符合IEC相关标准要求可自动执行8组状态泄漏电流的量测(7611,7620)可外接标准GPIB/RS232界面作控制20×2 点矩阵 LCD 显示器(7620)内建多组程序记忆组 (7611/7623 10组 7620 50组)前面板软件输入校正键盘锁定功能量测速度快,准确度高技术参数SPECIFICATIONSMODELCURRENT MEASUREMENTFrequencyRangeDC-1MHZCMRR>40dB@1MHZInput Impedance/Capacitance>1MΩ/<200pf`````````````````````````Leakage current (7611&7620)ResolutionAccuracy(DC-10KHZ)Accuracy(10K-1MHZ)0.0-999.9, μA0.1±(1.5%of reading 5counts)±(5%of reading 5counts)1000-6000, μA1±(1.5%of reading 2counts)±(5%of reading 5counts)Leakage current (7623)ResolutionAccuracy(DC-200KHZ)Accuracy(200K-1MHZ)0.0-999.9, μA0.1±(5%of reading 0.5 μA)±(5%of reading 2 μA)1000-9999, μA1LINE VOLTAGE MEASUREMENTRange0 - 300 VACResolution0.1 VAccuracy±(1%of reading 2counts)DUTDUT Input Power Rating30~300 VAC30~277 VACSingle Phase Unbalanced (One Hot or Line conductor and One Neutral)DUT Current Capacity30A10A20ADUT Production32A, Short circuit current11A, Short circuit current22A, Short circuit currentResponse Time < 600msecSETTINGSHigh /Low Trip, μA (7611&7620)Range 0-6000μA (0=OFF), Resolution 1μAHigh /Low Trip, μA (7623)Range 0-9999μA (0=OFF), Resolution 1μADelay Time, secondRange 0, 1.0-999.9 (0=continuous), Resolution 0.1secondMEASUREMENT DEVICE CIRCUIT  A/B/C/D/E/FA/E/FMD AUL 544 Non Patient、UL484、IEC60598、UL1363MD BUL 544 Patient CareMD CIEC60601-1, UL2601-1, EN 60601-1MD DUL1563MD EUL60950, IEC60950, IEC61010-1, UL3101-1, IEC60335-1, IEC60990MD FExternal MDGENERALInput Voltage115/230Vac±15%, 50/60Hz ± 5%, Fuse 2A/250V Slow-Blow fusePLC Remote ControlInput : Test , Reset , Memory1.2.3Output : Pass , Fail , ProcessingMemory10 memories, 8 steps/memory50 memories, 8 steps/memory10 memories, 8 steps/memoryDisplay16×2 LCD with back light20×2 LCD with back light20×2 LCD with back lightKey LockTo prevent unauthorized alteration of the test ParametersCalibrationBuild-in software and external calibrated metersInterfaceGPIB/RS232 (Option)Alarm Volume SettingRange: 0-9 ;0=OFF, 1 is softest volume, 9 is loudest volume.Environment0-40 ℃, 20-80%RHDimension430(W)×89(H)×400(D)mm430(W)×133(H)×400(D)mm430(W)×89(H)×400(D)mmNet Weight7.5Kg8.5Kg7.5KgSTANDARD ACCESSORIESPower Cord(10A)×1×2 (10A/15A)Fuses×2 (Including a spare contained in the fuse holder)Hipot Return Lead ,1.8m(1102)×2-DUT I/P Power Cord ,1.6m(1761)×1--DUT I/P Power Cord ,1.6m(1762)-×1-LLT Receptacle Adaptor Box20A ,1.6m(1905)-×1×1LLT Receptacle Adaptor Box20A ,1.6m(1906)×1--*product specifications are subject to change without notice.以上是台湾华仪7611泄漏电流测试仪的详细信息,如果您对台湾华仪7611泄漏电流测试仪的价格、厂家、型号、图片有什么疑问,请联系我们获取台湾华仪7611泄漏电流测试仪的新信息。