TESEQ NSG 3060A雷击浪涌发生器主要特色

One box solutionsystem Surge voltage up to 6.6 kVallows overtesting

Easy to use 7” color touch screen

IEC and ANSI coupling methodsParameters can be changed whiletest is running

Wide range of optional test accesories

High accuracy switching technology meets ANSI coupling requirements


Teseq’s new NSG 3060A conducted immunity generator takes the proven, user-friendly design of the highly successful NSG 3000series to a new level. This innovative design uses modular architecture to provide a versatile system that can be configured for basic testing needs and expanded to meet the needs of sophisticated test laboratories.


Designed to fulfill requirements for CE mark and ANSI C62.41 testing, the NSG 3060Aperforms tests for Combination wave surge, Ring wave and Electrical Fast Transient (EFT) pulses as well as Power Quality Testing (PQT). Extensive expansion capabilities enable the system to be configured for a muchbroader range of applications.


Using state of the art components, the self-contained modules set new standards with respectto switching and phase accuracy and exceed the existing standards’ requirements. With its powerfulprocessors, the NSG 3060Acan completely fulfill the unique coupling requirements specified by ANSIC62.41. This standard requires that the pulse amplitude be adjusted for the phase position of the pulseon the AC mains, and for the amplitude of the mains voltage.


TESEQ NSG 3060A雷击浪涌发生器主要参数

Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse)Pulse conforms to IEC/EN 61000-4-5 and ANSI (IEEE) 62.41image.png


Ring wave 0.5 μs/100 kHzPulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41image.png


Burst (EFT) 5/50 nsPulse conforms to IEC/EN 61000-4-4image.png


Dips & Interruptsconforms to IEC / EN 61000-4-11, IEC / EN 61000-4-29image.png


Variation test (with VAR 3005A-S16 only) image.png


Pulsed magnetic field in conjunction with MFC 30 conforms to IEC/EN 61000-4-9image.png


Power magnetic field in conjunction with MFT 30 or MFO 6501A and MFC 30 / MFC 300 conform to IEC/EN 61000-4-8image.png


TESEQ NSG 3060A雷击浪涌发生器选件

★CDN 3063A-C32 :Three phase 480 V / 32 A automatic coupling decoupling networksfor Burst/EFT up to 4.8 kV, Surge, Ring Wave pulses up to 6,6 kV

★CDN 3063A-C63 :Three phase 480 V / 63 A automatic coupling decoupling networkfor Burst/EFT up to 4.8 kV, Surge, Ring Wave pulses up to 6,6 kV

★CDN 3063A-C100 :Three phase 480 V / 100 A automatic coupling decoupling networkfor Burst/EFT up to 4.8 kV, Surge, Ring Wavepulses up to 6,6 kV

★CDN 3425:Burst EFT capacitive coupling clamp for data line coupling per IEC 61000-4-4

★CDN 117A-C7-4-1:Coupling networks for unsymmetrical signal-/data lines (surge)

★CDN 118A-C7-4-1:Coupling networks for symmetrical signal-/data lines (surge)

★CDN HSS-2 :Coupling network for 2 kV surge pulse 1.2 / 50 μs IEC/EN 61000-4-5 on unshielded symmetrical high speed telecom lines (Ethernet)

★PVFBKIT 1:Burst/EFT verification set

★MD 210 :Voltage differential probe 7 kVcommon / differential 1000:1 / 100:1

★MD 300: Current probe 5 kA

★TVT 1-250-16:Manual step transformer, 16 AAC, 0/40/70/80%

★VAR 3005A-S16 :Automatic single variable transformer, 1 x 16 A

★MFO 6501A:Manual magnetic field option -4-8

★MFC 30:Magnetic field coil 1 x 1 m, with MFO max. 40 A/m -4-8;Surge* max. 1200 A/m -4-9

★MFC 300:Magnetic field coil 1 x 1 m; max. 330 A/m -4-8