图文详情
-
产品属性
-
相关推荐
CLAMP-ON CURRENT SENSOR
(1A output)
Funions & Features
?Easy-to-install, spring-loaded, clamp-on te current sensor
?Over-voltage clamp element for safety in open circuit
?1 A output
?Wide frequency band
?Up to 20 kHz harmonic contents
?Screw terminal conneion
MODEL: CLSC–[1]
ORDERING INFORMATION
? Code number: CLSC-[1]
Specify&sp;a code from below for [1].
(e.g. CLSC-10)
[1] INPUT
10:&sp;100 A
25:&sp;250 A
50:&sp;500 A
60:&sp;600 A
CAUTION
Before you remove the sensor module or mount it, turn off the input signal for safety. While the line is alive, the module’s cores, attraed to each other, may be hard to separate.
RELATED PRODUS
AC current, watt, power faor transducers with 1 A input
? input module (model: R3-4)
?Multi power input module (model: R3-WT1)
?AC power input module (model: R3-WT4)
?AC current transducer (model: 14CE)
?AC current transducer (model: LTCE)
? tranitter (model: )
? tranitter (model: KCE)
? tranitter (model: M2CE)
? tranitter (model: M5)
?Multi power monitor (model: 53U, 54U)
GENERAL SPECIFICATIONS
Construion: Clamp
Conneion: M3 screw terminals (torque 0.3 N·m)
Housing material: Flame-resistant resin (black)
Detachable number of times: Approx. 100 times
INPUT SPECIFICATIONS
Max. working voltage: 480 V AC (primary side)
Overload capacity: 120 % continuous, 4000 % for 1 minute
Operational range
&sp; CLSC-10: ≤ 100 A
&sp; CLSC-25: ≤ 250 A
&sp; CLSC-50: ≤ 500 A
&sp; CLSC-60: ≤ 600 A
INSTALLATION
Operating temperature: -20 to +60°C (-4 to +140°F)
Operating humidity: 80 % RH max. (n-condensing)
Mounting: Fix&sp;with a binding strap.
Weight:
CLSC-10: 170 g (0.37 lbs)
CLSC-25: 175 g (0.39 lbs)
CLSC-50: 250 g (0.55 lbs)
CLSC-60: 265 g (0.58 lbs)
爱模 m-system CLSC-10&sp;
PERFORMANCE
Frequency: 50 / 60 Hz
Rated primary current / rated secondary current
CLSC-10: 100 A / 1 A
CLSC-25: 250 A / 1 A
CLSC-50: 500 A / 1 A
CLSC-60: 600 A / 1 A
Ratio error: ±1.0 %, 1.0 In
Phase displacement error
&sp; CLSC-10: +2±1°, 1.0 In
&sp; CLSC-25, -50, -60: +1±1°, 1.0 In
Insulation resistance: ≥ 100 MΩ with 500 V DC&sp;
(sensor core to output)
Dieleric strength: 2000 V AC @ 1 minute
(sensor core to output)
爱模 m-system CLSC-10&sp;