Accelerometer specifications All values are specified between -55°C (-67°F) to +95°C (203°F) and at 5.0 VDC supply
voltage, unless otherwise stated
Units RS9002.B
Full scale range g ± 2
Bias calibration @ 20oC mg < 10
Bias temperature coefficient @ 20°C μg/°C (max) ± 200
One year composite repeatability [1] μg (1σ) < 500
In run bias stability (48h) @ 20oC μg (max) < 100
Scale factor calibration @ 20oC mV/g 1000 ± 8
Scale factor temperature coefficient @ 20°C ppm/°C (max) 75 ± 100
One year composite repeatability [1] ppm (1σ) < 300
Input axis misalignment (Kp, Ko) μrad < 10’000
One year composite repeatability [1] μrad (max) < 1000
Non linearity % of FS (max) < 0.8%
Vibratioon rectification @ 20°C μg/g2 rms (1σ ) < 800 [60-2000Hz]
Bandwidth @ 20oC [2] Hz > 200
Noise spectral density in band @ 20oC ?g/?Hz (max) 30
[1] The one year composite repeatability represents the residual error stability defined according to IEEE 528-2001 and under following environmental conditions: turn on / on,
storage at -55°C and 85°C, -40°C to 125°C T cycling, vibration, shock (6000g, 0.2ms single shock in all directions).
[2] The bandwidth is defined as the frequency band for which the sensitivity has decreased by less than 3