-
图文详情
-
产品属性
-
相关推荐
G9EA-1-CA-48V功率继电器作用广泛,能够应用在很多领域,此继电器原理独特,性价比高,是一款值得您购买的高寿命继电器。欢迎来电咨询继电器报价并订购,量大继电器价格更优。
Item | G9EA-1(-B) | G9EA-1(-B)-CA | |
Contact resistance (See note 2.) | 30 mΩmax. (0.6 mΩtypical) | 10 mΩmax. (0.3 mΩtypical) | |
Contact voltage drop | 0.1 V max. (for a carry current of 60 A) | 0.1 V max. (for a carry current of 100 A) | |
Operate time | 50 ms max. | ||
Release time | 30 ms max. | ||
Insulation resistance (See note 3.) | Between coil and contacts | 1,000 MΩmin. | |
Between contacts of the same polarity | 1,000 MΩmin. | ||
Dielectric strength | Between coil and contacts | 2,500 VAC, 1 min | |
Between contacts of the same polarity | 2,500 VAC, 1 min | ||
Impulse withstand voltage (See note 4.) | 4,500 V | ||
Vibration resistance | Destruction | 10 to 55 to 10 Hz, 0.75-mm single amplitude (Acceleration: 2.94 to 88.9 m/s2) | |
Malfunction | 10 to 55 to 10 Hz, 0.75-mm single amplitude (Acceleration: 2.94 to 88.9 m/s2) | ||
Shock resistance | Destruction | 490 m/s2 | |
Malfunction | 196 m/s2 | ||
Mechanical endurance (See note 5.) | 200,000 ops. min. | ||
Electrical endurance (See note 6.) | 120 VDC, 100 A, 3,000 ops. min. | 400 VDC, 30 A, 1,000 ops. min. | |
400 VDC, 60 A, 3,000 ops. min. | 120 VDC, 30 A, 2,500 ops. min. | ||
400 VDC, 30 A, 30,000 ops. min. | — | ||
Short-time carry current | 100 A (10 min) | 150 A (10 min) | |
Maximum interruption current | 600 A at 300 VDC (5 times) | — | |
Overload interruption | 180 A at 400 VDC (100 times min.) | 100 A at 120 VDC (150 times min.) | |
Reverse polarity interruption | –60 A at 200 VDC (1,000 times min.) | — | |
Ambient operating temperature | –40 to 70°C (with no icing or condensation) | ||
Ambient operating humidity | 5% to 85% | ||
Weight | Approx. 310 g |