本款二合一笔记本充电器,是一款集合了,家用,车用,飞机用,与一体的多功能电源,带有USB,和LCD显示



2.0 INPUT REQUIREMENTS

2.1 VOLTAGE

The range of input voltage is from AC 100 Vac to 240Vac.

 

2.2 FREQUENCY

The range of input frequency is from 47Hz to 63Hz.

 

2.3 DC INPUT

Dc Input: 12Vdc

2.4 CURRENT

The maximum input current is 2.0A at 90Vac.

 

2.5 INRUSH CURRENT

The inrush current will not exceed 30A at 110Vac input, cold start, 25.

3.0 OUTPUT REQUIREMENTS

3.1 Static load:

Output#

Voltage

Minimum Load

Maximum load

Peak load

1

5V

0A

1A

1.5A

2

  12V

      0A

      4.5A

   13A

    3

  15V

      0A

      4.5A

   11A

    4

  16V

      0A

      4.5A

   10A

    5

  18V

      0A

      4.5A

   9A

    6

  19V

      0A

      4.5A

   9A

    7

  20V

      0A

      4.5A

   8A

    8

  24V

      0A

      3.75A

   8A

3.2 Output voltage

The output voltage shall be statically regulated for all combinations of load,

line and environment including cross regulation as shown.

Output#

Voltage

Range

Tolerance

1

5V

4.75V-5.25V

±5%

2

   12V

11.4V-12.6V

±5%

3

   15V

14.3V-15.7V

±5%

4

   16V

15.2V-16.8V

±5%

5

   18V

17.1V-18.9V

±5%

6

   19V

18.1V-19.9V

±5%

7

   20V

19.0V-21.0V

±5%

8

   24V

22.8V-25.2V

±5%

Table 3.1.2

3.3 Ripple and noise

Output#

Voltage

Maximum peak to peak ripple & noise

1

5V

240mVp-p

2

12V

240mVp-p

3

15V

240mVp-p

4

16V

240mVp-p

5

18V

240mVp-p

6

19V

240mVp-p

7

20V

240mVp-p

8

24V

240mVp-p

Table 3.1.3

Measuring is done by 20MHz bandwidth oscilloscope and terminated each

output with a 10uF capacitor and a 0.1uF capacitor.

 

3.4 Temperature coefficient:

±0.05%/typical on all output.

3.5 Hold – up time:

8 msec minimum from loss of nominal AC input at full load condition,

110VAC input, output will remain within regulation.

 

3.6 Rise Time:

Input 110VAC,Power turn - on 2s. Max.

 

3.7 Efficiency:

The efficiency (watts out / watts in) is higher than80%typical while

measuring at nominal line and rated load.