- Connects to any computer via RS232 or IEEE-488.
- Motorized slits.
- Triple-grating turret allows high efficiency scanning across a broad spectral range.
- May be factory configured as a monochromator or spectrograph.
- Scans in both directions and with Constant Spectral Resolution (CSR).
- Integrates with SP filter wheel for automatic filter switching.
- Suitable for fluorescence and absorption studies, detector characterization, thin film measurements, etc.
The Workhorse: Direct Digital Drive/Constant Spectral Resolution The Digikrom DK240 is a complete computer integrated solution. Easy to use commands control the triple grating turret, motorized slits, and optional motorized filter wheel for quick and easy sorting. Instrument mode can be set for constant spectral resolution (CSR), where the slit width is automatically modified to compensate in the change in dispersion with wavelength to maintain constant spectral bandpass. Rugged cast construction, A-Thermal design, and SP direct grating drive make this unit the most repeatable and reliable in its class. Each instrument is calibrated and certified prior to delivery. Feature ValueDesign: | Czerny-Turner. Triple-grating turret standard. | Focal Length: | 240mm | f/#: | 3.9 | Wavelength Drive: | Worm and wheel with computer control. Bi-directional. | Wavelength Precision and Reproducibility: | 0.007nm (with 1200g/mm grating) | Wavelength Accuracy: | ± 0.30nm standard (with 1200 g/mm grating) | Scan Speed: | 1 to 1200nm/minute (with 1200g.mm grating) | Stray Light: | < 0.01% at 220nm (Nal) | Slits: | Unilateral, computer controlled, curved entrance and straight exit standard. Width - 10μm to 3000μm Height - 2mm to 20mm | Reciprocal Dispersion: | 3.2nm/mm (with 1200 g/mm grating) | Max Resolution: | 0.06nm (with 1200 g/mm grating) | Gratings: | One to three gratings (68 x 68mm standard, 68 x 84mm optional) must be purchased. See Appendix A for options. | Software: | Demonstration control program and LabView driver included. | Power: | 100 - 240V, 50/60Hz, 60W 220/230/240V, 50/60Hz @ 0.5A optional. | Interface: | RS232 standard | Weight: | 35 lbs. | Warranty: | One year | Options: | - DKBS - Bi-lateral slits
- DKGPIB - IEEE-488 communication interface (internal)
- DK2400 and Hand-held controllers for local control
- IR240 - Gold optics
- DK2PORT - Bifurcated fiber bundle for attaching 2 devices to 1 port.
- AB300 - Automated 6 position filter wheel
See options and accessories |
DK480 1/2 Meter Monochromator | |
| | - Connects to any computer via RS232 or IEEE-488.
- Motorized slits.
- Triple-grating turret allows high efficiency scanning across a broad spectral range.
- May be factory configured as a monochromator or spectrograph.
- Scans in both directions and with Constant Spectral Resolution (CSR).
- Integrates with SP filter wheel for automatic filter switching.
- Suitable for fluorescence and absorption studies, detector characterization, thin film measurements, etc.
Wavelength Selection is No Longer Expensive The Digikrom DK480 is a complete computer integrated solution. Easy to use commands control the triple grating turret, motorized slits, and optional motorized filter wheel for quick and easy sorting. Instrument mode can be set for constant spectral resolution (CSR), where the slit width is automatically modified to compensate in the change in dispersion with wavelength to maintain constant spectral bandpass. Rugged cast construction, A-Thermal design, and SP direct grating drive make this unit the most repaetable and reliable in its class. Each instrument is calibrated and certified prior to delivery. Feature ValueDesign: | Czerny-Turner. Triple-grating turret standard. | Focal Length: | 480mm | f/#: | 7.8 | Wavelength Drive: | Worm and wheel with computer control. Bi-directional. | Wavelength Precision and Reproducibility: | 0.007nm (with 1200g/mm grating) | Wavelength Accuracy: | ± 0.3 nm standard (with 1200 g/mm grating) | Scan Speed: | 1 to 1200nm/minute (with 1200g.mm grating) | Stray Light: | < 0.01% at 220nm (Nal) | Slits: | Unilateral, computer controlled, curved entrance and straight exit standard. Width - 10μm to 3000μm Height - 2mm to 20mm | Reciprocal Dispersion: | 1.60nm/mm (with 1200 g/mm grating) | Max Resolution: | 0.03nm (with 1200 g/mm grating) | Gratings: | One to three gratings (68 x 68mm standard, 68 x 84mm optional) must be purchased. See Appendix A for options. | Software: | Demonstration control program and LabView driver included. | Power: | 100 - 240V, 50/60Hz, 60W 220/230/240V, 50/60Hz @ 0.5A optional. | Interface: | RS232 standard | Weight: | 45 lbs. | Warranty: | One year | Options: | - DKBS - Bi-lateral slits
- DKGPIB - IEEE-488 communication interface (internal)
- DK2400 and Hand-held controllers for local control
- IR480 - Gold optics
- DK2PORT - Bifurcated fiber bundle for attaching 2 devices to 1 port.
- AB300 - Automated 6 position filter wheel
See options and accessories |
|
DK242 1/4 Meter Double Monochromator | |
| | - Internal controller connects to any computer via RS232 or IEEE-488. Hands-off control of three slit assemblies and two grating turrets.
- Scans in both directions and with Constant Spectral Resolution (CSR).
- Triple-grating turrets allows high efficiency scanning across a broad spectral range.
- Additive dispersion increases resolution and reduces stray light for Raman and fluorescence studies, subtractive dispersion minimizes broadening of pulse sources.
- Integrates with SP filter wheel for automatic filter switching.
- May be factory configured as a monochromator or spectrograph.
The Pioneer: Better Resolution, Stray Light Control The DK242 is two cascaded monochromators, with the exit slit of the first monochromator functioning as the entrance slit of the second. This instrument may be factory configured to operate as either an additive or subtractive dispersion double monochromator. In both modes, the two monochromators act as a double filter with the rejection of stray light being nearly the square of the single monochromator value. In the additive dispersion mode, the DK242 is the equivalent of a half-meter monochromator, but permits greater reduction of stray light. The first grating spreads the spectrum over an angular range; the second grating then doubles this dispersion. The result is twice the resolution of a single 1/4-meter monochromator. In subtractive dispersion mode the first monochromator selects a bandpass. The second monochromator then removes the temporal and angular aberrations introduced by the angular spectral dispersion in the first monochromator. The DK242 offers a unique solution to practical problems in the spectroscopy of pulsed sources. For example, an ordinary monochromator will introduce up to 250 pico second broadening in light pulses that are passed through the monochromator. Operated in the subtractive dispersion mode, the DK242 reduces this broadening to almost zero because the second monochromator equalizes the optical path length of the first. The DK242 is also a unique solution to the practical problems of Raman spectroscopy because the high stray light rejection of the two monochromators allows observation close to the laser line. SP's unique CSR scanning technology also improves efficiency in the red and near IR while maintaining resolution. (In the CSR mode, the monochromator's change in dispersion with wavelength is compensated by a change in slit widths while bandpass remains constant. Intensity improvement up to 4x can occur). Equipped with SP's Direct Digital Drive, the DK242 is a complete computer-controlled instrument. The control electronics are internal, calibration is automatic. Any computer can control the DK242 through its RS232 interface with simple commands (shown in all capital letters) to direct the monochromator to GO TO a wavelength, to SCAN between wavelengths at a preset SPEED, to SELECT gratings, or to report its STATUS. Feature ValueDesign: | Double cascaded Czerny-Turner. Triple-grating turrets standard in each section. | Focal Length: | 240mm each section. | f/#: | 3.9 overall | Wavelength Drive: | Dual worm and wheel with electronic synchronization and computer control. Programmable in additive or subtractive dispersion | Scan Speed: | > 1 to 1200nm/minute (with 1200 g/nm grating) | Stray Light: | < 10-9 | Slits: | Unilateral, computer controlled, Width - 10μm to 3000μm Height - 2mm to 20mm | Gratings: | Two to six gratings (68 x 68mm standard, 68 x 84mm optional) must be purchased. See Appendix A for options. | Wavelength Precision: | 0.01nm (additive) 0.01nm (subtractive) | Wavelength Accuracy: | ± 0.3nm (additive) ± 0.3nm (subtractive) | Reciprocal Dispersion: | 1.60nm/mm (additive) --- (with 1200 g/mm grating) | Max Resolution: | <0.04nm (additive) 0.06nm (subtractive) | Pulse Broadening: | 200 ps max (additive) 10 fs max (subtractive) | Interface: | RS232 standard | Software: | Demonstration control program and LabView driver included. | Power: | 110 / 120V, 50/60Hz @ 1A standard. 220/230/240V, 50/60Hz @ 0.5A optional. | Warranty: | One year | Options: | - DKBS - Bi-lateral slits
- DKGPIB - IEEE-488 communication interface (internal)
- DK2400 and Hand-held controllers for local control
- IR240 - Gold optics
- DK2PORT - Bifurcated fiber bundle for attaching 2 devices to 1 port.
- AB300 - Automated 6 position filter wheel
See options and accessories |
DK Series Options and Accessories | |
| | DKBS Bi-lateral slit option for DK240/242/480. Both sides of slits are automatically controlled for maintaining image centering when wider slits are necessary (tolerance ± 10μm). DKGPIB Internal IEEE-488/GPIB communication interface option for DK240/242/480. Separate output connector from Monochromator. IR240 For use with DK240. Infrared (gold) coatings on optics for DK240. Enhances transmission by up to 40% between 600 -1100nm. Not suitable for work below 600nm. IR240SP Same as above, for use with DKSP240 IR242 For use with DK242. Infrared (gold) coatings on optics for DK242. Enhances transmission by up to 80% between 600 - 1100nm. IR242SP Same as above, for use with DKSP242 IR480 For use with DK480. Infrared (gold) coatings on optics for DK480. Enhances transmission by up to 40% between 600 -1100nm. IR480SP Same as above, for use with DKSP480 DK2401 Hand-held monochromator controller for DK240/242/480. Allows local control of monochromator when computer is not available or in series with a computer. DK24PS RS232 Cable assembly for PS/2 style computer DK24MA RS232 Cable assembly for MAC style computer DK24IC IEEE-488/GPIB universal cable assembly AB300 Six position, 1" diameter automatic filter wheel assembly that bolts directly to DK entrance. Recieves power and commands directly through DK unit. See page 92 for more information. DKSP-TO-DK Attachment to allow DKSP Spectrograph to operate as a monochrometor. It includes CM standard 6-fixed slit set (page 17). AB200 Single filter carrier that mounts directly between DK unit and accessories DK Series Standard Gratings, 68 x 68 mm | |
| | Part # Ruling(g/mm) Peak(nm) Range(nm) Peak(%T)AG2400-00240-686 | 2400 | 240 | 180 - 680 | 70 | AG1200-00200-686 | 1200 | 200 | 180 - 450 | 65 | AG1200-00250-686 | 1200 | 250 | 180 - 460 | 70 | AG1200-00300-686 | 1200 | 300 | 200 - 750 | 72 | AG1200-00500-686 | 1200 | 500 | 330 - 1000 | 83 | AG1200-00600-686 | 1200 | 600 | 400 - 1500 | 80 | AG1200-00750-686 | 1200 | 750 | 480 - 1500 | 85 | AG1200-01000-686 | 1200 | 1000 | 550 - 1500 | 75 | AG0600-00500-686 | 600 | 500 | 350 - 1300 | 80 | AG0600-01200-686 | 600 | 1200 | 800 - 3000 | 85 | AG0600-01600-686 | 600 | 1600 | 950 - 3000 | 93 | AG0300-00500-686 | 300 | 500 | 310 - 1100 | 80 | AG0300-02000-686 | 300 | 2000 | 1200 - 4000 | 88 | AG0300-02500-686 | 300 | 2500 | 1500 - 6000 | 88 | AG0300-03000-686 | 300 | 3000 | 1800 - 6000 | 80 | AG0 | 150 | 500 | 320 - 980 | 72 | AG0 | 150 | 4000 | 2500 - 9000 | 93 | AG0075-08000-686 | 75 | 8000 | 5000 - 15000 | 82 | AG0050-00600-686 | 50 | 600 | 400 - 1200 | 78 | AG0050-12000-686 | 50 | 12000 | 7500 - 20000 | 82 |
NOTE: Ruled gratings blazed at other wavelengths and holgrahic gratings are available on request.
|
|
|
|