        UI3000测试仪是UI2000电子镇流器综合测试仪的增强型,完全继承了UI2000仪器的各项技术性能,并增加了单个高频波的测量。满足IEC60929IEC60969IEC61000-3-2GB/T15144-2005GB/T17263-1998电子镇流器电性能测试要求。

UI3000采用了目前国际上较为先进的12位超高速A/D转换器,采样速率高达10MHz。可以真实测试单个高频波的波形,为技术人员深入研究电子镇流器的工作机理、进行可靠性分析提供了强有力的工具和手段。

    UI3000 tester is UI2000 electronic ballast radiocomm.tester of enhanced, fully inherited UI2000 instrument of various technical performance, and increases the single high frequency wave measurement. Meet IEC60929, IEC60969, IEC61000-3-2, GB/T15144-2005, GB/T17263-1998 electronic ballast e-test requirements.

    UI3000 adopts the international advanced 12 ultra-high speed A/D converter, highest sampling rate as high as 10MHz. Can a single high frequency wave real-life test waveforms, for the technical staff in-depth study electronic ballast of the working mechanism, the reliability analysis provides powerful tools and methods.

性能:

◆测量参数:

◇ 输入:电压、电流、功率、功率因数、电网频率、相位角、总谐波及0~39次各谐波分量

◇ 输出:灯电压、灯电流、灯丝电流、导入阴极电流、灯功率、波峰系数、振荡频率、高频波单个波分析

◇ 启动:启动过程灯电压、灯电流、灯丝电流、导入阴极电流变化曲线及参数,预热时间

◇ 预热能量测试:预热能量及灯丝预热启动时间,电子镇流器启动后0~5秒内灯丝电压、灯丝电流、灯丝功率的变化曲线

◆ 输入: ±(0.1% reading+0.1% range+1 digit)

◆ 输出: ±(1% reading+1% range+2 digit)

◆ 八窗口显示输入特性、输出特性各参数,便于比较、分析

◆ 输入电流测试频响1MHz,能够准确测量各类电子镇流器

◆ 分析灯电流包络波的对称性

◆ 引入超高速采样技术,可动态分析单个高频波,采样频率高达10MHz

◆ 测试快速,1秒钟实现输入、输出各参数测试

◆ 便携型,内含单片微机,尤其适用于开发和现场生产,能够打印各参数及波形、曲线

◆ 可以与PC机通讯,提供专用软件,在中文版Windows98/2000/XP/Vista下运行,人机界面好,美观,操作方便;中英文版面同时提供

Properties:

measuring parameters:

So the input voltage, current, power, power factor, the grid frequency, phase Angle, total harmonic and 0 ~ 39 times each harmonic component

So the output voltage, current, lamp lights, filament current, import cathodic current, lamp power, wave coefficient, oscillation frequency, high frequency wave single wavelet analysis

So start: the start-up process lamp voltage, current, the filament lamp current, import cathodic current curve and parameter, preheating time

So preheating energy test: preheat energy and filament preheating start time, electronic ballast after the launch of 0 ~ 5 seconds filament voltage, current, the filament filament power change curve

input precision: + (0.1% reading + 0.1% HTML + 1 digit)

output precision: + (1% reading + 1% HTML + 2 digit)

eight window shows input characteristics, output characteristic parameters, facilitate comparison and analysis

Should the input current test frequency response 1MHz, can accurate measurement of electronic ballasts

lamp current envelopment analysis of wavelet symmetry

Should introduce ultra-high speed sampling technique, can a single high frequency wave dynamic analysis, the highest 10MHz sampling frequency up

test rapidly, 1 second realize input and output parameters testing

portable type, contains the single chip microcomputer, especially suitable to development and on-site production, able to print various parameters and waveform, curve

can with the PC communications, provide specialized software, in Chinese Windows 98/2000 / XP/Vista run, man-machine interface, better appearance, convenient operation, Chinese and English forum also offer