Specifications | Model CVH | Model HATR-T2 | Model CH | |
Working Platform | Cuvette Holder | Horizontal Platform | Card Reader | |
Min. Detection Limit | 2 ppm | 8 ppm | 40 ppm | |
(Oil in water) | ||||
Min. Detection Limit | 10 ppm | 40 ppm | 200 ppm | |
(TPH in soil) | ||||
Solvent | Perchloroethylene, Freon-113, S-316 | Hexane, Pentane, Vertrel MCA | Hexane, Pentane, Vertrel MCA | |
Component Measured | Measures all hydrocarbons | Measures hydrocarbons with a boiling point higher than the solvent - volatile hydrocarbons will be evaporated along with the solvent | Measures hydrocarbons with a boiling point higher than the solvent - volatile hydrocarbons will be evaporated along with the solvent | |
Instrument Repeatability | ±1 ppm | ±2 ppm | ±4 ppm | |
Typical Applications | Oil in Water/Wastewater | Oil in Water/Wastewater | Very high levels of Oil in Water | |
Oil in Produced Water | Oil in Produced Water | TPH in Soil | ||
Fats, Oil & Grease (FOG in Wastewater Discharges) | Fats, Oil & Grease (FOG in Wastewater Discharges) | |||
Oil in Frac Water | Oil in Frac Water | |||
TPH in Soil | TPH in Soil | |||
Samples with Light-End Volatile Components | ||||
Other Instructions | Solvents are heavier than water and require a separatory funnel or inverted vial with a septa cap to collect a solvent sample. | Solvents are lighter than water and solvent sample can be collected from the top of the container. | Solvents are lighter than water and solvent sample can be collected from the top of the container. | |
Ordering Information | InfraCal TOG/TPH Analyzers | |||
405-1009 | InfraCal IR Platform Analyzer, HATR-T2 Complete with HATR-T2 Stainless Steel Trough Sample Stage with Built-in Cubic Zirconia ATR Crystal, Power Supply and Instruction Manual. | |||
405-0003 | InfraCal Cuvette Holder Analyzer, Model CVH Complete with CVH Sample Stage for use with 10 mm Quartz Cuvette Cells, Power Supply and Instruction Manual. | |||
405-0002 | InfraCal Card Reader Analyzer, Model CH Complete with CH Sample Stage for use with InfraCal Reusable IR Sample Plates with Sapphire Window, Power Supply and Instruction Manual. | |||
Sample Handling Accessories | ||||
403-0012 | Set of four 10mm Quartz Cuvette Cells with Teflon stopper for use with Model CVH | |||
403-0010/5 | InfraCal Reusable IR Sample Plates with Sapphire Window, Set of 5 for use with Model CH | |||
Accessories | ||||
403-0018 | InfraLog Serial Printer, Model DT2205 Prints calibration and measurement data, complete with sequence number, date and time. Includes all required cables. Note: This printer is only for use with InfraCal Analyzers | |||
403-0013 | Carrying Case for InfraCal Analyzers | |||
403-0002 | 12V Automotive Power Adapter Cable | |||
403-0005 | Dust Cover | |||
Field Sampling Kits | ||||
403-1010 | Field Sampling Kit for TPH in Soil | |||
403-1011 | Field Sampling Kit for TOG/TPH in Water for Model HATR-T2 | |||
403-1063 | Field Sampling Kit for TOG/TPH in Water for Model CVH | |||
Replacement Parts | ||||
403-0001 | Universal Switching Power Supply and Line Cord for use with InfraCal Analyzers. 90-264 VAC, 50-60 Hz input, regulated 12v/25 watt output. | |||
403-0014 | Replacement Source/Cable Assembly | |||
Additional One and Two Year Extended Factory Warranties | ||||
EWOY | Extended Factory Warranty for additional One Year (total two year factory warranty from date of shipment). | |||
EWTY | Extended Factory Warranty for additional Two Years (total three year factory warranty from date of shipment). |