图文详情
-
产品属性
-
相关推荐
Standards: According to the clause 1060 (vertical burning and FT1 test), 1061(cables burning test), 1080(VW-1 burning test), 1090(electric cable specimen horizontal burning test, optional item), 1100 (horizontal specimen/ FT2 burning test)of UL1581-2008, 6.8(standard arcing test), clause 9.1~9.5 of UL2556-2007, clause 4.26 of JIS C3005-2000,ASTM D 5025,ASTM D 5027
Scope: Apply to check the single cable flaming test for FT1, FT2/FH/Horizontal flame, FV-2/VW-1, FV-1/Vertical flame, and standard arcing test;
Technical parameters:
1. Testing Chamber: L2200*D1300*H1650mm, capacity>4.0 m3;upper capacity of flame is more than 2.0m3, there is glass windows on the face, a pair of operational rubber gloves and smoke exhaust system on the top of the chamber;
2. Bunsen burner: Which according toASTM D5025-2005standard, Inside diameter of the burner tube is 9.5mm by length is 100mm, the Gas spout diameter is 0.9mm by thickness is 1.6mm. Which burn gas is methane at 98% minimum purity, the inner flame height is 40±2mm, the outer flame height is 125±10mm, nominal rate is 500W with a flame ruler which can check the flame height whether it meet requirement at any time.
Temperature measurement system: According toASTM D5207-2003standard, including 10g temperature measurement copper pieces, Type K stainless steel thermal which diameter is 0.5mm,stopwatch and thermometer。