图文详情
-
产品属性
-
相关推荐
Sigle-phase/Up to 7 functions
automatic production lines for home appliances.
Technical characteristics:
◆ International Electrical Safety Standard: Compliant with IEC60335, UL60335, GB4706.1-2005, GB4943 standard requirements;compliant with JJG795-2004, JJG984-2004, JJG843-2007, JJG690-2003, etc. regulation requirements.
◆ High-speed Comprehensive Test: Up to 7 functions comprehensive; Adopt synchronous double-channel & Parallel testing proprietary technology.The fastest speed is 1s in one function.
◆ High Precision Measurement: Compliant with standard requirements for safety test, the precision is 2%, for power test, the precision is 5%.
◆ Intelligent SPC Operations: 15-group / 8-step test condition, auto compensation, auto judgment, auto protection, auto memory.
◆ Network System Management: Configure with multi-interface; Achievable Automation and network management in workshop, remote collecting, recording,analyzing and monitoring data , cooperate with the client LAN software.
◆ Human Interface: 10.4 inch TFT LCD display, menu, online help.
Product Technical Parameters:
Model No. | AN9652H (7 Test Functions in 1) | |||
Ground Bond Test | ||||
Empty Load Output Voltage | <12V | |||
Output Current Setting Range | AC 3A~30A 50Hz/60Hz, 1A/step | |||
Output Current Setting Accuracy | ±(2% of setting+0.2A) | |||
Resistance Limit Setting Range | Upper limit:3A≤output current≤10A, 10~600mΩ; 10A 25A Lower limit: 0~100mΩ | |||
Ground Bond Resistance Resolution | 1mΩ | |||
Ground Bond Resistance Measurement Range/ Accuracy | 10~600mΩ, ±(2% ×reading+2mΩ) | |||
Compensation Resistance Measurement Range/Accuracy | 0~200mΩ 1mΩ | |||
Test Time Setting Range | 0.5~999.9s 0.1s/step | |||
Insulation Resistance Test | ||||
Rated Output Load/Current | 1VA (1000V/1mA) 1mA | |||
Output Voltage Range/ Adjustable rate | DC:500V/1000V <1% (Empty load to full load) | |||
Output Voltage Ripple | Pure resistance load, 1000V/1mA, <3% | |||
Output Voltage Accuracy/Resolution | ±(2% of setting+2V) 5V/step | |||
Insulation Resistance Range | 1.0~2000MΩ | |||
Insulation Resistance Lower Limit Setting Range/ Resolution | Lower limit:1.0~99.9 MΩ, 0.1MΩ/step, 100~2000 MΩ 1 MΩ/step Upper limit:1.0~99.9~2000 MΩ | |||
Insulation Resistance Accuracy | 1~200 MΩ: ±(2% of reading+2counts) , 200~2000 MΩ: ±(5% of reading+5counts) | |||
Ramp-up Time Range/Resolution | 0.1~999.9s 0.1s | |||
Delay Judgment Time | 0.3~10.0s (Count from ramp-up ) | |||
Test Time Setting Range | 0.5~999.9s 0.1s/step | |||
AC Hipot Test | ||||
Rated Output Load | 500VA (AC:5000V/100mA) | |||
Output Voltage Range/Frequency/ Adjustable Rate | 500~5000V, 50Hz/60Hz, <2%(Empty load to full load) | |||
Output Voltage Setting Range | Static state AC:500~5000V, Dynamic state AC:500~2500V, 5V/step | |||
Output Voltage Accuracy | ±(2.5% of setting+5V) | |||
Breakdown Current Preset range | Upper limit: 0.10~99.99mA; Lower limit: 0.00~99.99mA , 0.01mA/step | |||
Compensation Current Setting Range/ Resolution | 0.00 ~5.00mA, 0.01mA | |||
Output Initial Voltage Range | (0%~99%) of test voltage, from 0V to initial voltage need 200ms | |||
Breakdown Current Measurement Range/Resolution | 0.10~99.99 mA, 0.01mA | |||
Breakdown Current Measurement Accuracy | ±(2% of reading +2counts) | |||
Test Time | 0.5~999.9s | |||
Ramp-up Time Range | 0.1~999.9s | |||
Ramp-down Time Range | 0.0~999.9s(After test pass) | |||
DC Hipot Test | ||||
Rated Output Load | 60VA (DC:6000V/10mA) | |||
Output Voltage Range/ Adjustable Rate | 500~6000V, <2%(Empty load to full load) | |||
Output Voltage Setting Range | Cold state DC:500~6000V, Hot state DC:500~2500V, 5V/step, | |||
Output Voltage Setting Accuracy | ±(2.5% of setting+5V) | |||
Breakdown Current Preset range | Upper limit: 50~9999μA; Lower limit: 0~9999μA , 1μA | |||
Compensation Current Setting Range/ Resolution | 0 ~5000μA, 1μA | |||
Output Initial Voltage Range/ Resolution | (0~99%) of test voltage, from 0V to initial voltage need 200ms | |||
Breakdown Current Measurement Range/Resolution | 50~9999μA , 1μA | |||
Breakdown Current Measurement Accuracy | ±(2% of reading +2counts) | |||
Test Time | 0.5~999.9s | |||
Ramp-up Time Range | 0.1~999.9s | |||
Ramp-down Time Range | 0.30~10.0s(Count from ramp-up) | |||
Leakage Current Test | ||||
Output Voltage Range | 1.06 times of input voltage (output by single-phase isolated transformer, voltage regulation 5%) | |||
Leakage Current Range/Resolution | Upper limit: 50~9999μA 1μA | |||
Compensation Current Setting Range/ Resolution | 0~500μA 1μA | |||
Test Time Range/Resolution | 1.0 ~999.9s 0.1s | |||
Leakage Type | dynamic, static | |||
Output Voltage Measurement Range | AC 50~500.0V 0.1V | |||
Output Voltage Measurement Accuracy | ±(0.5% of reading+2counts) | |||
Leakage Current Measurement Range | 50~9999μA 1μA | |||
Leakage Current Measurement Accuracy | DC~10kHz: ±(2% of reading+5counts) 10kHz~1MHz: ±(5% of reading+5counts) | |||
Leakage Power | Single phase, 6kVA | |||
Power Test | ||||
Output Voltage Range | 1.00 times of input voltage (output by single-phase isolated transformer, voltage regulation 5%) | |||
Power Setting Range/Resolution | Upper limit, Single phase:20~62000W Lower limit, Single phase:0~62000W | |||
Test Time Range/Resolution | 0.5 ~999.9s 0.1s | |||
Voltage Measurement Range and Accuracy | AC:50.0V~500.0V, 45~65Hz: ±(0.5% of reading +2counts) | |||
Current Measurement Range and Accuracy | AC:0.30~30.00A, 45~65Hz: ±(0.5% of reading +2counts) | |||
Active Power Measurement Range and Accuracy | 20.0~999.9W; 1.000~6.000kW; 45~65Hz: ±(0.5% of reading +2counts) | |||
Power Factor Range and Accuracy | 0.100~1.000, ±(2% of reading +2counts) | |||
Low Voltage Start Test | ||||
Output Voltage Range | 0.85 times of input voltage (output by single-phase isolated transformer, voltage regulation 5%) | |||
Test Time Range/Resolution | 0.5 ~999.9s 0.1s | |||
Current Setting Range/Resolution | Upper limit: 0.30 ~30.00A Lower limit: 0.00 ~30.00A 0.01A | |||
Voltage Measurement Range and Accuracy | AC:50.0V~500.0V, 45~65Hz: ±(0.5% of reading +2counts) | |||
Current Measurement Range and Accuracy | AC:0.30~30.00A, 45~65Hz: ±(0.5% of reading +2counts) | |||
Display Mode | 10.4 Inch, 640×480, TFT LCD display | |||
Isolated Transformer Capacity | Single Phase 6 KVA | |||
Over Current Protection | Power, Start, Leakage Current, Phase Current 35A, over 5s protection | |||
Equipment style | Single Phase | |||
Grounding Mode | Load Grounding, Load Floating | |||
DUT Error Processing | Voice and light alarm | |||
Outer Alarm Light | Red alarm light | |||
PLC Output Interface | OK, NG and finished test output | |||
Interface | RS232 CPM, Outer Printer COM, Remote COM | |||
Optional Interface | RS485 COM, Internet Card COM, Inner Printer | |||
Test Group | 15 groups, 8 steps / group | |||
Buzzer Alarm Voice | Able to be turned ON or OFF |