-
图文详情
-
产品属性
-
相关推荐
- 产品品牌:
- TECHNIX
- 产品型号:
- 7500-20000J/s CCR系列
法国TECHNIX高压充电电源,主要作为高压电容器以及MARX发生器等设备的充电电源。
These chargers constitute the high end range. Double Resonance Technology operating at high frequencies (50 kHz) offers a smooth switching to all the critical components and provides them a non-stressing behaviour.
Internal power dissipation, harmonics & ripple are significantly reduced.
Hence, they can operate without damage or interruption in rugged environments Many of them are used at full power 24 h/day, 7 days/week with no failure for many years. Four ranges of charge rates are offered in this series from 7.5 kJ/s to 20 kJ/s.
For higher charge rates, they can be configured to run in master/slave mode to reach 50 kJ/s and more.
An oil tank is integrated for the models from 20 kV and more.
- Voltage & Current Ouputs continuously adjustable from 0 to full scale
- Low stored energy
- High Efficiency
- Total protection against arcs, overloads and short circuits
- Customized V and C full scales* with no extracost
- V & C Setting and Monitoring from front panel or REMOTE
- High precision regulation
- Remote, Inhibit & Interlock functions
- High reliability
- Compact design
- Double Resonance Technology (ZVC)
- Automatic crossover
- Over Current Limitation and Protection functions
- Polarity display
- Safety switch key
- Master-slaves architecture allowing to go beyond 40 kW
* You can choose your own full scales (Vmax and Imax) even if these values are not available in standard. For example, you can get a 15 000 V generator based on 30 000 W model. In this case, you will get an Output Voltage adjustable from 0 to 15 000 V and an Output Current from 0 to 2 A.
Both Voltage Output and Current Output are continuously adjustable from 0 to 100 % (full scale).
In local mode: by using 10 turns potentiometers resolution 0.05%
In remote mode: by an external 0 to 10 V
Load Regulation: ±0.05 % of full voltage (for 0 - 100 % load change); ±0.01% available on request.
Line Regulation: ±0.05 % of full voltage ( for Main Voltage ±10 %); ±0.01% available on request.
Load Regulation: ± 0.05 % (for 0 - 100 % load change)
Line Regulation: ± 0.05 % (for Main Voltage ± 10 %)
0.1 % p-p
0.1% RMS for single phase models
< 100 ms, 10 ms available on request
0.01 % / hour, 0.03 % after / 8 hours of operating with constant load and ambiant temperature.
100 ppm/°C
from 0 to 40°C
> 92 % full load
< 1 mS
1J / kW
Dust filter fans on front panel. Easily removable filters for cleaning.
400 VAC ± 10 % 47 - 63 Hz 3 Phases + Earth from 1500 W
> 0.98
with probes periodically approved by Authorized Measurement Laboratories