- 产品品牌:
- TECHNIX
- 产品型号:
- 2500-5000J/s CCR系列
法国TECHNIX高压充电电源,主要作为高压电容器以及MARX发生器等设备的充电电源。
- Voltage & Current Outputs continuously adjustable from 0 to full scale
- High precision regulation
- Total protection against arcs, overloads and short circuits
- Over Temparature protection
- High reliability & efficiency
- Double Resonance Technology (ZVC)
- V & C Setting and Monitoring from front panel or REMOTE
- Automatic crossover
- Over Current Limitation and Protection functions
- Remote, Inhibit & Interlock functions
- Polarity display and 3½ digit displays
- Safety switch key
- Master-slaves architecture or Control Unit to 6 modules
* You can choose your own full scales (Vmax and Imax) even if these values are not available in standard. For example, you can get a 45 000 V generator based on 6 000 W model. In this case, you will get an Output Voltage adjustable from 0 to 45 000 V and an Output Current from 0 to 133.3 mA.
- Output Voltage and Output Current:
Both Voltage Output and Current Output are continuously adjustable from 0 to 100 % (full scale).
In local mode: by using 10 turns potentiometers resolution 0.05%
In remote mode: by an external 0 to 10 V
- Reproducibilty (pulse to pulse voltage variation):
Load Regulation: ± 0.25 % (Frequency < 10 Hz)
Line Regulation: ± 0.1 % ( for Main Voltage ± 10 %)
- Current regulation:
Load Regulation: ± 0.05 % (for 0 - 100 % load change)
Line Regulation: ± 0.05 % (for Main Voltage ± 10 %)
- Voltage Holding:
0.25 % p-p (better on request)
- Stored Energy:
0.2J/kJ
- Protections:
Against short circuit & HV arc to ground
Shutdown on Overtemperature, & open interlock
- Temperature Coefficient:
100 ppm/°C
- Efficiency:
> 90 % full load
- Stability (after one hour warm-up):
0.01 % / hour, 0.03 % / 8 hours of operating with constant load and ambient temperature.
- Temperature Coefficient:
100 ppm/°C
- Operating Temperature:
from 0 to 40°C
- Air Cooling
- Mains Voltage:
400 VAC ± 10 % 47 − 63 Hz 3 Phases + Earth
- Inrush current:
limited to full power operating current
- Power factor:
> 0.98
- Calibration:
with probes periodically approved by Authorized
Measurement Laboratories
- CE Marking