美国MPETS Series可编程直流电源、PV模拟电源
价格:电议
地区:
电 话:86-021-37524113
传 真:86-021-37524113
产品品牌:
美国MPE
产品型号:
TS Series
类型:
其它

Key Features

  • Very high power density:
    Up to 15 kW in a 3U package
  • Wide voltage and current range:
    Models up to 0-4000 Vdc and 0-2700 Adc
  • Load dependent air cooling:
    Variable speed fans on all models
  • Wide range of input voltages:
    From 208 Vac to 480 Vac, 50 Hz to 400 Hz
  • Front panel analog potentiometers:
    Stepless rotary control
  • 37-pin optically isolated user I/O:
    No additional circuitry necessary
  • RS-232 interface standard:
    Optional IEEE 488.2 GPIB, USB, LXI TCP/IP Ethernet, RS-485 interfaces
  • CE Mark
  • Made in the USA

Specifications

 

Input

Nominal Voltage
3 phase, 3 wire + ground
208 VAC (operating range 187 - 229 VAC)
240 VAC (operating range 216 - 264 VAC)
380 VAC (operating range 342 - 418 VAC)
415 VAC (operating range 373 - 456 VAC)
440 VAC (operating range 396 - 484 VAC)
480 VAC (operating range 432 - 528 VAC)
1 phase, 2 wire + ground 208 VAC (operating range 187 - 229 VAC)
240 VAC (operating range 216 - 264 VAC)
Frequency 50 through 400 Hz
Power Factor Greater than 92% at maximum power for 3 phase models,
Greater than 70% at maximum power for 1 phase models.
 

Environmental

Operating Temperature 0°C to 50°C
Storage Temperature -25°C to +85°C
Ambient Temperature 0 to 50°C
Temperature Coefficient 0.04%/°C of maximum output voltage,
0.06%/°C of maximum output current.
Air Cooling (Standard) Side air inlet, rear exhaust
Water Cooling (Optional) 25°C maximum inlet temperature
1.5 GPM minimum flow rate for 15 kW units
3.0 GPM minimum flow rate for 20-30 kW units
4.5 GPM minimum flow rate for 45 kW units
80 PSI maximum pressure
1/4” NPT female pipe size
 

Physical

Power Input Phases Size (H" x D" x W") Rack Units Weight
5 kW
10 kW
15 kW


5¼" x 24" x 19" (13.34 x 60.96 x 48.26 cm)
10½" x 24" x 19" (26.67 x 60.96 x 48.26 cm)
15¾" x 24" x 19" (40.01 x 60.96 x 48.26 cm)
3U
6U
9U
75 lbs (34.02 kg)
150 lbs (68.04 kg)
225 lbs (102.06 kg)
5 kW
10 kW
15 kW
20 kW
25 kW
30 kW
45 kW






5¼" x 24" x 19" (13.34 x 60.96 x 48.26 cm)
5¼" x 24" x 19" (13.34 x 60.96 x 48.26 cm)
5¼" x 24" x 19" (13.34 x 60.96 x 48.26 cm)
10½" x 24" x 19" (26.67 x 60.96 x 48.26 cm)
10½" x 24" x 19" (26.67 x 60.96 x 48.26 cm)
10½" x 24" x 19" (26.67 x 60.96 x 48.26 cm)
15¾" x 24" x 19" (40.01 x 60.96 x 48.26 cm)
3U
3U
3U
6U
6U
6U
9U
74 lbs (34.57 kg)
94 lbs (42.64 kg)
125 lbs (56.70 kg)
195 lbs (88.45 kg)
220 lbs (99.79 kg)
245 lbs (111.13 kg)
365 lbs (165.56 kg)
 

Output

Ripple See Model Charts
Line Regulation Voltage Mode: ± 0.004% of full scale
Current Mode: ± 0.02% of full scale
Load Regulation Voltage Mode: ± 0.01% of full scale
Current Mode: ± 0.04% of full scale
Load Transient Response 2 ms to recover within ±1% of regulated output with a 50% to 100% or 100% to 50% step load change
Efficiency ≥ 86%; See Model Charts
Stability ± 0.10% for 8 hrs. after 30 min. warmup
Isolation Maximum input voltage to ground: ±2500 Vac

Maximum output voltage to ground:
±1000 Vdc for models less than or equal to 1000 Vdc,
±(2000 Vdc + Vo/2) for models greater than 1000 Vdc where Vo is the maximum output voltage of the power supply.

User inputs and outputs: referenced to earth ground.

Maximum Slew Rate Standard Models:
100 ms for an output voltage change from 0 to 63%,
100 ms for an output current change from 0 to 63%.

With High-Slew Rate Option
4 ms for an output voltage change from 0 to 63%,
8 ms for an output current change from 0 to 63%.

Bandwidth Standard Models:
3 Hz with remote analog voltage programming,
2 Hz with remote analog current programming.

With High Slew Rate Option:
60 Hz with remote analog voltage programming,
45 Hz with remote analog current programming.

Analog Output Impedances Voltage output monitoring: 100 ohm
Current output monitoring: 100 ohm
+10V Ref: 1 ohm
 

Programming Levels and Accuracy of Full Scale

  Voltage
Set Point
Current
Set Point
OVT
Set Point
OCT
Set Point
Remote Analog Programming Accuracy ± 0.50% ± 0.75% ± 0.50% ± 0.75%
Digital Programming Accuracy ± 0.50% ± 0.75% ± 0.50% ± 0.75%
Remote Analog Programming Levels 0 - 10.0 Vdc 0 - 10.0 Vdc 0 - 10.0 Vdc 0 - 10.0 Vdc
 

Monitoring Levels and Accuracy of Full Scale

  Output Voltage Output Current
Remote Analog Monitoring Accuracy ± 0.50% ± 0.75%
Digital Monitoring Accuracy ± 0.50% ± 0.75%
Remote Analog Monitoring Levels 0 - 10.0 V 0 - 10.0 V
 

Control Limits

Remote Sense Limits 3% maximum voltage drop from output terminals to load.  Remote sense is not available for models with output voltages greater than 1000 Vdc.
Period Programming Limits Minimum period: 10 msec
Maximum Period: 9997 sec or 2.77 hours
Digital control inputs and outputs limits Input voltage: 0 to 5 Vdc, 10K input impedance;
Output voltage: 0 to 5 Vdc, 5 mA drive capacity
5 V supply: 25 mA.