型号 | S-320 | S-320 | S-320 | S-320 | S-320 | S-320 | S-320 | S-320 | |||
输出 | 直流输出电压 | 5V | 7.5V | 12V | 13.5V | 15V | 24V | 27V | 48V | ||
输出电压容差(注3) | ±2% | ±2% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | |||
额定输出电流(注5) | 50A | 36A | 25A | 22A | 20A | 12.5A | 11A | 6.5A | |||
输出电流范围 | 0-50A | 0-36A | 0-25A | 0-22A | 0-20A | 0-12.5A | 0-11A | 0-6.5A | |||
输出功率 | 250W | 270W | 300W | 297W | 300W | 300W | 297W | 312W | |||
纹波及噪音(注2) | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 240mVp-p | |||
直流电压可调范围 | -10%,+14% | ±20% | -16%,+10% | -12%,+11% | -10%,+20% | -16%,+10% | -4%,+18% | -15%,+17% | |||
启动、上升、保持时间 | 2s,20ms,20ms满载 | ||||||||||
输入 | 输入电压范围 | 88~132 VAC/176~264VAC 47~63 Hz;由开关选择248~370VDC | |||||||||
交流输入电流 | 6A/115 V 3.5A/ 230 V | ||||||||||
效率 | 77% | 80% | 82% | 83% | 84% | 86% | 86% | 87% | |||
冲击电流 | 冷启动电流20A/115V 40A/230V | ||||||||||
漏电流 | <3.5mA/240VAC | ||||||||||
保护特性 | 过载保护 | 105%~135% | |||||||||
保护方式:打嗝模式,自动恢复 | |||||||||||
过电压保护 | 115%~135% | ||||||||||
保护方式: 打嗝模式 ,自动恢复 | |||||||||||
风机控制O.T.P | RT1≥65℃风机开,≤55℃风机关,≥70℃切断输出 (5~15V) | ||||||||||
RT1≥70℃风机开,≤65℃风机关,≥80℃切断输出 (24~48V) | |||||||||||
环境 | 工作温度、湿度 | -10℃~+60℃;20%~90 %RH | |||||||||
保存温度、湿度 | -20℃~+85℃;10%~95 %RH | ||||||||||
抗震性 | 10~500Hz,2G 10min./1周期,时长60分钟,各轴 | ||||||||||
安全 | 耐压性 | 输入输出间:3KVAC 输入与地:1.5KVAC 输出与地:0.5KVAC | |||||||||
绝缘电阻 | 输入输出间,输入与地,输出与地: 100M Ohms/500VDC | ||||||||||
符合标准 | 安全标准 | 符合UL1950 | |||||||||
EMC标准(注4) | 符合EN55022,EN55024,EN61000 | ||||||||||
其它 | 重量 | 1.08Kg | |||||||||
包装 | 12pcs/13.5Kg/0.93CUFT | ||||||||||
备注 |
|