PXW5,PXW7,PXW9型号已淘汰,对应的替代产品为PXR5,PXR7,PXR9。
PXR系列温控器简介:◆双排显示PV、SV等数据;
◆多种热电偶信号、热电阻信号、线形信号输入;
◆带手/自动模式,切换便利; ◆ 8段斜坡/保温程序(选件)
◆满量程0.5%,85-256V AC 50/60HZ供电工作。
◆ 再传输输出功能DC4-20ma和RS485通讯功能(选件)
◆遥控输入功能(选件)
◆数字量输入多2点(选件):通过一点开关量ON/OFF,可改变设定值SV,控制动作起/停,斜坡/保温控制的开始/ 复位,自动调节功能的起/停,报警锁存的复位、定时器计时开始;
◆二路输出(选件):用于加热/冷却控制 ◆ 加热断线报警(选件)
◆自带一路报警功能:多3点(选件)。
富士温控表PXR4/5/7/9系列选型说明数字位 | 规格面板尺寸W×H | 代号 | 4 | 5 | 6 | 7 | 8 | - | 9 | 10 | 11 | 12 | 13 | 4 | 48×48mm | 4 | | | | | | | | | | | 48×96mm | 5 | | | | | | | | | | | 72×72mm | 7 | | | | | | | | | | | 96×96mm | 9 | | | | | | | | | | | 5 | 输入信号 | | | | | | | | | | | | 热电偶(℃) | | T | | | | | | | | | | 热电偶(℉) | | R | | | | | | | | | | RTD/Pt100欧姆(℃) | | N | | | | | | | | | | RTD/Pt100欧姆(℉。) | | S | | | | | | | | | | 1~5V DC | | A | | | | | | | | | | 4~20mA DC | | B | | | | | | | | | | 6 | 控制输出1 | | | | | | | | | | | | 继电器接点输出 | | | A | | | | | | | | | SSR/SSC驱动输出 | | | C | | | | | | | | | 4~20mA DC输出 注1 | | | E | | | | | | | | | 7 | 控制输出2 | | | | | | | | | | | | 无 | | | | Y | | | | | | | | 继电器接点输出 | | | | A | | | | | | | | SSR/SSC驱动输出 | | | | C | | | | | | | | 4~20mA DC输出 | | | | E | | | | | | | | 再传输输出(4~20mA DC) | | | | R | | | | | | | | 8 | 版本号 | | | | | 1 | - | | | | | | 9. | 附加功能1 | | | | | | | | | | | | 无报警 | | | | | | | 0 | | | | | 1个报警 | | | | | | | 8 | | | | | 加热器断路报警 注2 | | | | | | | 2 | | | | | 1个报警+加热器断路报警 注2 | | | | | | | 3 | | | | | 8段斜坡/保温程序 | | | | | | | 4 | | | | | 1个报警+8段斜坡/保温程序 | | | | | | | 5 | | | | | 加热器断路报警+8段斜坡/保温程序 注2 | | | | | | | 6 | | | | | 1个报警+加热断路报警+8段斜坡/保温程序 注2 | | | | | | | 7 | | | | | 两个报警 | | | | | | | F | | | | | 两个报警+8段斜坡/保温 | | | | | | | G | | | | | 两个报警+加热器断路报警+8段斜坡/保温 注2 | | | | | | | H | | | | | 3个报警 | | | | | | | M | | | | | 遥控设定 注2 | | | | | | | D | | | | | 遥控设定+2个报警 注2 | | | | | | | P | | | | | 10 | 操作说明书 电源电压 | | | | | | | | | | | | 中文 100~240VAC | | | | | | | | W | | | | 日文 100~240VAC | | | | | | | | Y | | | | 英文 100~240VAC | | | | | | | | V | | | | 无 24VAC/24DC | | | | | | | | C | | | | 日文 24VAC/24DC | | | | | | | | A | | | | 英文 24VAC/24DC | | | | | | | | B | | | | 11 12 13 | 附加功能2 | | | | | | | | | | | | 无 | | | | | | | | | 0 | 0 | 0 | RS485(Modbus)通讯 | | | | | | | | | M | 0 | 0 | RS485(Z-ASC11) 通讯 | | | | | | | | | N | 0 | 0 | 1点数字输入 | | | | | | | | | S | 0 | 0 | 2点数字输入 注3 | | | | | | | | | T | 0 | 0 | RS485(Modbus) 通讯+1点数字输入 | | | | | | | | | V | 0 | 0 | RS485(Z-ASC11) 通讯+1点数字输入 | | | | | | | | | W | 0 | 0 | 注1:输出4-20mA不能与加热器断路报警一起选。(即选项9中的2、3、6、7、H) | 注3:若选择2点数字输入,输出2或加热器断路报警不能选。 | 注2:不能与RS485+1点数字输入一起选。(即选项11、12、13中的V00) |
|