特点
参数:一:机体材质:1:5MM进口灰白耐冲击P.V.C板,耐高温达85℃,耐腐蚀2:支物<<0MM玻璃棒,耐腐蚀。塑钢V形架与不锈钢管角置物,确保试物成30度斜角.3:压力桶采<.0MMSUS304不锈钢板无缝焊接4:发热采用钛管. 使用寿命<耐腐蚀程度<5:机盖采用5MM进口透明
德国YLIS)压克力板制<做工精细,外形美观,透明度高<控制系统<
台湾YANGMING温度控制,数字显示PID自动演算,SSR输出,高稳定
白金测温探头。盐雾试验时温度误为±1℃ 压力桶采用亨利定律,于以加温加湿,实验室湿度达到95%以上,符合国家标准三:计时系统:采用高多功
日本OMRON计时器,试验时间可设定多功能化,可设<.001S—9999H.直至产品完成要求时间。积时器数字显示四:补水系统:采用自<手动加水系统,具有水位不足时自动/手动补水功能。实验不中断,满足客人多元化环境要求<自动补水只需接入自来水管即可)五:加热方式:盐雾实验时采用蒸汽直接加温方式,升温速度快,温度分布均匀,减短待机时间六:控制方式:五键式标准型操作。带全侦测故障预警系统。故障发生时可亮灯 五键式操作为一个电源开关、一个操作开关、喷雾开关、计时开关、及除雾开关。实验时打开电源开关仪器自动加<加水完成后打开操作开<设定好实验温<仪器自动加温,打开喷雾开关仪器喷雾开始,打开计时,设定时间,实验时间完成后结<内置手动除雾功能.可在实验过程中摆放或查看产品除去实验积存盐雾七:安全保护装置 附双重超温保护(
意大利KGB),在出现温控表故障或加热系统故障时可自动切断加热电源。避免温度过高损坏仪器 双重低水位保护,防止实验室及压力桶发热管干烧损坏 附超载短路保护。防止出现异常时损坏仪表及仪器内部电控配件<附实验实盐水桶低盐位提醒,避免盐水做完后实验异<八:计量筒:采用
内置式雾量收集筒两个。比传统的外置式相比更不易碰坏<喷嘴:精密型石英玻璃喷<保证使用4000个小时不结晶. 喷雾塔附锥形分散器,具有导向雾气、调节节雾量、及均匀落雾等功能<密封方式:内外箱体连接密封<采用水密<防止盐雾外泄.十一:控制面板及电器配< 温控器(台湾YANGMING<NBSP;&NBSP;&NBSP; 两个< DIV> 压力表(台湾KK<NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP; DIV 一<> 指示灯(台湾<NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP; DIV 六个<> 计时器(日本欧姆龙) 一 积时<(台湾YANGMING HM-1< 一 控制开<(台湾) 五个 SSR (台湾阳明) 两个 继电器(日本欧姆龙) 三个 感温线(台湾神捷<NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP; DIV 两条<> 调压阀(AIRTAC<NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP; 两个< DIV> 电磁阀(日本KSD<NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP; DIV 四个<> 水位器(台湾翔阳<NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP; DIV 四个<> 发热管(钛管<NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP; DIV 一<> EGO (意大利KGB<NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP; DIV 一<> 空气过滤器(台湾AIRTAC<NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP; DIV 一<> 十二:附件说明: V型支物架 6 O型支物棒 8 氯化<NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP; DIV 两瓶<> 十三:温度范围:1:实验室温度<5<-50℃(可任意设定) 2:压力桶温度<7<-63℃(可任意设定)十四:升温速度1:实验室,常<--<5<NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP; DIV <5分钟<> 2:压力桶,常<--<7<NBSP;&NBSP;&NBSP;&NBSP;&NBSP;&NBSP; DIV <5分钟<> 十五:温度:±1十六:功<60/90型AC220V 50HZ 15A 本机适用于中性盐雾试验(NSS)及腐蚀实验(AASS、CASS)
规格
项目 LTEN | 型号 MODEL |
Zy-60 | Zy-90 | Zy-120 |
试验室尺 mm | 600*450*400 | 900*600*500 | 1200*1000*500 |
外箱尺寸 mm | 1070*600*1180 | 1410*880*1280 | 1900*1200*1400 |
试验室温 | 盐水试验35±1/耐腐蚀试验50±1 |
饱和桶温 | 盐水试验47±1/耐腐蚀试验63±1 |
酸碱 | 盐水试验(6.5~7.2)/耐腐蚀试验(3.0~3.2) |
喷雾 | 1.0~2.0ml/h |
试验室相对湿 | 85% |
氯化钠溶液浓 | 5% |
试验室容 | 108L | 270L | 600L |
盐水箱容 | 15L | 25L | 40L |
电源 | AC220V1 10A | AC220V1 15A | AC220V1 30A |