前置放大器5660B, 5660C, 5662, 5670, 5676, 5
价格:电议
地区:
电 话:86-010-57727576
手 机:18901052321
传 真:86-010-58126636
产品品牌:
Olympus NDT
产品型号:
5660B, 5660C, 5662, 5670, 5676, 5678, 5682

Preamplifiers: Models 5660B, 5660C, 5662, 5670, 5676, 5678, 5682

The ultrasonic preamplifier models for use with ultrasonic flaw detection, thickness gaging, and acoustic emission instrumentation provide very low noise amplification of ultrasonic signals.

Olympus wideband series of Panametrics AC coupled, broadband preamplifiers provides very low noise amplification of ultrasonic signals ranging from 500 Hz to greater than 40 MHz. Specifically designed for use with ultrasonic flaw detection, thickness gaging, and acoustic emission instrumentation, our preamplifiers are a cost-effective solution in general applications requiring high gain/low-noise amplification of low amplitude ultrasonic signals.

Our preamplifiers are ruggedly housed, completely self-contained, simple to operate, battery or AC powered units. They offer performance features such as very low noise (5 µV peak-to-peak noise referred to the input in Model 5660B), input protection for high voltage transients such as transducer excitation pulses, and the ability to drive long coaxial cables (greater than 500 feet or 152 meters with Models 5660B and 5660C). Both fixed gain and switchable gain versions are available, and custom units with special gain or bandwidth are available on special order.

Applications

Certain ultrasonic applications require the addition of a separate preamplifier unit to standard test systems in order to provide the additional gain or broadband signal-to-noise enhancement necessary for optimum signal acquisition. This is often the case in industrial applications involving flaw detection or thickness gaging of thick sections of materials exhibiting high ultrasonic attenuation such as nodular cast iron, brass, bronze, austenitic steel, rubber, Teflon®, or reinforced composites. A preamplifier is also an important component of acoustic emission test systems that require amplification of low signal amplitude events and the ability to drive long cables from remotely located sensors. 
Panametrics preamplifiers have also been used in many widely diversified research applications including seismic studies, determination of the size and number versus scattered frequency relationship for acoustic scatterers in water (gas bubbles, zooplankton), crack detection in graphite vacuum arc-melt electrodes, and biological tissue analysis.

NEW - MODEL 5682

The Model 5682 Ultrasonic Preamplifier provides low noise amplification of ultrasonic signals ranging from 500 KHz to 25 MHz. The preamplifier, housed in a rugged splash-proof enclosure, is very small and lightweight making it ideally suited for remote applications. The preamplifier can be powered with either a single 9 V battery for up to 50 hours of continuous operation or a local 9 V to 13 V DC supply (customer supplied). When battery operated, a multicolored LED provides feedback on battery status. This preamplifier is ideal for AUT and TOFD scanning. 

Inclusions: The unit is supplied with one 9 V alkaline battery. All cables are sold separately and are offered in a variety of lengths and connector styles to accommodate transducer, instrumentation, and applications requirements.

Specifications*

MODEL 5660B 5660C 5662 5670 5676 5678
Voltage Gain 
(Inverting)
40 and 60 dB 
Switchable 
(RL > 1K ohm)
40 and 60 dB 
Switchable 
(RL > 1K ohm)
34 and 54 dB 
Switchable 
(RL = 50 ohm)
40 dB 
Fixed 
(RL = 50 ohm)
40 dB 
Fixed 
(RL = 50 ohm)
40 dB 
Fixed 
(RL = 50 ohm)
Bandwidth 
(-3dB)
20 kHz - 
2 MH
500 Hz - 
2 MHz
50 kHz - 
5 MHz
50 kHz - 
10 MHz
50 kHz - 
20 MHz
200 kHz - 
40 MHz
Equivalent Input 
Noise
5 µV p-p 5 µV p-p 10 µV p-p 15 µV p-p 20 µV p-p 30 µV p-p
Input 
Resistance
1M ohm 1M ohm 100K ohm 100K ohm 100K ohm 100K ohm
Input 
Capacitance 
(pf)
approx. 320 approx. 320 approx. 80 approx. 80 approx. 80 approx. 80
Input
Protection 300 V peak (Pulse Width <2 µs, 1% Maximum Duty Cycle)
Output 5 V p-p (RL > 1 K ohm)
Voltage 2 V p-p (RL = 50 ohm) 2 V p-p (RL = 50 ohm)
Output
Impedance

50 ohms in series with 4.7 fd

Max. Output >500' (152 m) 50' (15 m)
Power 16 V ± 2 V supplied by 4 Alkaline 9 V, 655 mAh batteries
Requirements Line operated units available. Add /110 VAC, /115 VAC, or /230 VAC to the Model Number (e.g. 5675/115 VAC).
Current 
Consumption
28 mA 28 mA 28 mA 32 mA 32 mA 36 mA
Battery 
Life
>40 hrs >40 hrs >40 hrs >35 hrs >35 hrs >35 hrs
Dimensions 3" W x 2" H x 5" D (76 mm W x 51 mm H x 127 mm D)
Weight

1.4 lbs. (0.64 kg)

Operating 
Temperature
32° F to 122° F (0° C to 50° C)

*All specifications are subject to change without notice.

NEW - Model 5682 Ultrasonic Preamplifier

Voltage Gain: 30 dB @ 10 MHz 
HighPassRollover: 0.5 MHz +/- 0.1 MHz 
LowPassRollover: 31 MHz +/-1 MHz 
Equivalent Input Noise: 11.5 µV RMS 
Input Impedance: Nominally 700 ohms 
Output Impedance: Nominally 50 ohms 
Output Voltage: 2.5 V pk-pk 
Protection: 500 V peak 
Current Consumption: Nominally 14 mA 
Power: 9 V alkaline battery or 9-13 V DC input (toggle switch) 
Power Monitor: Three color LED for continuous power level indications 
• Green: 7.0 - 9.0 V 
• Yellow: 6.5 - 7 V 
• Red: 5.0 - 6.5 V 
• No light: <5.0 V (Low charge, replace battery) 
BatteryLife:
>50 hours continuous operation 
Connectors: Lemo® 00 Type 
Dimensions: 2.25" x 4.3" x 1.1", 
57.15 mm x 109.22 mm x 27.94 mm 
Weight:
6.4 oz, 181 gr with battery; 
4.8 oz, 136 gr without battery 
Operating Temperature:
32° F to 122° F; 
0° C to 50° C 
Environmental: IP65