图文详情
-
产品属性
-
相关推荐
Fireye价格优惠! Fireye红外扫描仪,fireye 70D41控制器, Fireye control价格优惠!原装美国进口火焰检测器,Fireye紫外线扫描仪,Fireye Relay, Fireye module, Fireye紫外传感器,fireye价格,85UVF1-1QD价格,Fireye紫外传感器,Fireye火警报警仪, Fireeye 紫外,Fireeye火焰..Fireeye 燃烧控制器
---------------
Fireye 70D41, For manually ignited burners, 230 VAC Burner Management Controls provide ignition and flame failure protection for manually started oil or gas
产品介绍:
70D40 Control and Cover
72D1R1 Plug-in amplifier
48PT2 Flame Scanner (specify cable length and mount)
60-1386-2 Wiring Base
Fireye D40-41 controls supersede similar Fireye C-Series controls and are directly plug-in replaceable.
The following chart illustrates the comparison.
Control 70D40 with Amplifier 72DUV1 will also replace a Fireye Type 25DU4 model 5040 provided
the wiring is changed to the appropriate wiring shown later in this document.
Note: When a C-Series unit is replaced with a D-Series unit, the chassis retaining clip (for a quarter
turn fastener) in the wiring base must be replaced with a threaded clip that is supplied with each DSeries
Control.
A. Code 1 terminal load ratings all models: B. Terminal Load ratings for 70D40 Code 2 Models:
Max. Rating of each external load terminal: TERMINAL MAXIMUM RATINGS
125 VA PILOT DUTY TERMINAL 7 ONLY: Alternate
Rating — 300 VA transformer
and 130 VA pilot duty; and maximum
combined load of not more
than 3 motorized valves —
Holding — 180 VA
Opening— 635 VA
Locked Rotor — 730 VA
3, 5, 6, 8, X, A
120 VAC 230 VAC 7
Code 2
or higher
models only
250 VA Pilot Duty or Motor rating as given below:
5 amps 2.5 amps Voltage 120 VAC 230 VAC
125 VA
Pilot Duty
125 VA
Pilot Duty
FULL LOAD 9.8 A 5.1 A
LOCKED ROTOR 58.8 30.6 A
C. CE Load ratings for 70D41
TERMINAL MAXIMUM RATING AT 253 VAC
3, 5, 6, 8, 13, D 1A RESISTIVE OR (cos ? = 1)
7, A, M, P, X 4.5A RESISTIVE OR (cos ? = 1)
D SERIES C SERIES
OBSOLETE PART NUMBER COMPONENTS
D40-5030 Control 70D40 - Amplifier 72D1R1 Type 26DF4 - Model 5030
D41-5131 Control 70D41 - Amplifier 72D1R1T Type 26DF4 - Model 5131
D40-5060 Control 70D40 - Amplifier 72DUV1 Type 25DU4 - Model 5060
D41-5161 Control 70D41 - Amplifier 72DUV1T Type 25DU4 - Model 5161
D40-5050 Control 70D40 - Amplifier 72DRT1 —
D41-5151 Control 70D41 - Amplifier 72DRT1T —
DESCRIPTION OF FIREYE SERIES D40-41 COMPONENTS
Control Chassis and Cover Amplifier Flame Scanner
Use with
70D40 (120VAC) 50-60 Hz
or
70D41 (230VAC) 50/60 Hz
Rectification
72DRT1 2-4 sec. FFRT
72DRT1T 1 sec. FFRT
69ND1-1000K4
69ND1-1000K6
69ND1-1000K8
1/2" mount 12" (300mm) flame rod.
1/2" mount 18" (450mm) flame rod.
1/2" mount 24" (600mm) flame rod.
Infrared (IR) “Autocheck”
72D1R1 2-4 sec. FFRT
72D1R1T 1 sec. FFRT
*72D1R3 2-4 Sec. FFRT
*72D1R3T 1 Sec. FFRT
* For specific applications see note
below.
48PT2-1003
48PT2-9003
48PT2-1007
48PT2-9007
1/2 straight mount 96" (2400mm) cable.
1/2 angle mount 96" (2400mm) cable.
1/2" straight mount 48" (1200mm) cable.
1/2" angle mount 48" (1200mm) cable.
Ultraviolet (UV)
72DUV1 2-4 sec. FFRT
72DUV1T 1 sec. FFRT
UV8A
UV1A3
UV1A6
UV2
UV90-3, -6, -9
45UV3-1050
1/2" angle mount 72" (1800mm) wire (no cable).
1/2" straight mount 36" (900mm) cable.
1/2" straight mount 72" (1800mm) cable.
3/8" straight mount 36" (900mm) cable.
90º side opening, 36" (900mm), 72" (1800mm),
or 108" (2700mm) cable.
3/4" straight mount cast aluminum housing,
72" (1800mm) wire (no cable).
70D40 Only 72DUVS4 Repetitive Self-Check
2-4 sec. FFRT
72DUVS1T Repetitive Self-Check
1 sec. FFRT
45UV5-1009
or
45UV5-1008
1" NPT mount 72" (1800mm) wire (no cable),
120VAC shutter.
or
1" BSP mount 72" (1800mm) wire (no
cable),120VAC shutter.
70D40M Only Infrared (IR) AUTOCHECK
72D1R3TM 1 sec. FFRT
For special applications see Note
below.
48PT2-1003
48PT2-9003
48PT2-1007
48PT2-9007
1/2" straight mount 96" (2400mm) cable.
1/2" angle mount 96" (2400mm) cable.
1/2" straight mount 48" (1200mm) cable.
1/2" angle mount 48" (1200mm) cable.
70D41 Only 72DUVS1T or 72DUVS4 45UV5-1007 1" BSP mount 72" (1800mm) wire, no cable.
230VAC shutter
Wiring Base 60-1386-2 Standard base for surface mounting
60-1466-2 Open base for cabinet mounting
NOTE: Infrared “AUTOCHECK” amplifier modules 72D1R3, 72D1R3T, and 72D1R3T may be used for burner applications firing special
fuel such as sawdust, sander dust, low BTU gas. The 72D1R3 type amplifiers are not to be used on any liquid fuel fired burner as it may
result in malfunction causing damage to property and/or injury to personnel.
ACCESSORIES / SPARE PARTS
Part No. Description Used with Part No. Description Used with
4-263-1 Firetron Cell 48PT2 60-801 1/2" Coupling w/Pyrex Window 48PT2
4-314-1 UV Tube 45UV5, 45UV3 60-1199-1 1" NPT Coupling w/Quartz Window 45UV5-1009
10-88 Set of 3 orifice plugs 48PT2 60-1199-2 1" BSP Coupling w/Quartz Window 45UV5-1009
35-69 1/2" NPT Heat Insulator 48PT2-UV1 60-1257 1/2" Coupling w/Quartz Window UV1A
35-127-1 1" NPT Heat Insulator 45UV-1290 1/2" Coupling w/Quartz Lens UV1A
35-127-3 1" BSP Heat Insulator 45UV5-1007/8 60-1664-3 1" NPT Swivel Mounting Flange 45UV5-1009
46-38 Quartz Lens 45UV5 60-1664-4 1" BSP Swivel Mounting Flange 45UV5-1007/8
60-302 Swivel Mounting Flange 48PT2, UV1A 61-436 Lens Cap 48PT2