ABB分析仪器电导率探头TB26/TB27
价格:电议
地区:
电 话:86-020-38897067
手 机:13360550980
传 真:86-020-38897067
产品品牌:
ABB
产品型号:
TB26,TB264,TB27

Conductivity Cell TB26

The Conductivity Cell TB26 are easily installed into process lines and vessels via the integral 3/4 in. NPT threads, submersed directly into lines and vessels via the 1/2 in. NPT backthreads, or inserted into a process line or vessel through a ball valve. The ball valve provides isolation between the sensor and the process, allowing sensor insertion and removal while the line or vessel is full. This is accomplished by using a 1-1/2 in. standard ball valve. A compression fitting with flushing ports allows the operator to wash away any left over process fluid after removing the sensor. The flushing ports also provide a quick and easy place to take a grab sample for calibration. Variable sensor lengths are available for all Model TB26 sensor styles. The hot-tap sensor can be used with the compression fitting and without the ball valve to provide even greater installation flexibility.
  • Easy installation, available in hot-tap or inline / submersible configurations
  • Measurement ranges from 0 ... 1.999 µS/cm to 0 ... 19.99 mS/cm
  • Corrosion resistant 316 stainless steel measurement electrodes
  • Pt100 or Pt1000 integral temperature compensation elements
  • Anti-blowout lip on hot-tap versions is machined into sensor body
  • Interchangeable and replaceable sensor tips
  • Maximum temperature 200 °C (392 °F)
  • Maximum pressure 1551 kPa (255 psi)


Conductivity Cell TB264

The Conductivity Cell TB264 can be installed either inline via a 25 mm style fitting or used for flow cell applications. Inline applications consist of using an existing 25 mm port or purchasing a bushing and holder nut. Flow cell installations allow users to easily calibrate and isolate the sensor for maintenance.
  • Easy installation into either flow cell or any available 25 mm port
  • Measurement ranges from 0 ... 1.999 µS/cm to 0 ... 19.99 mS/cm
  • Corrosion resistant 316 stainless steel measurement electrodes
  • Pt100 or Pt1000 integral temperature compensation elements
  • Maximum temperature 200 °C (392 °F)
  • Maximum pressure 1379 kPa (13.79 bar / 200 psi)

Conductivity Cell TB27

The Conductivity Cell TB27 can be inserted or removed from process lines or vessels via a ball valve without disturbing the process. The TB27 sensor is designed for applications that exceed standard hot-tap sensor pressure ratings and for operator safety. An extraction housing isolates the operator from the process fluid. This housing has 1/4 in. ports for flushing, draining, pressurizing, or depressurizing this chamber. Ruggedly constructed of 316 stainless steel, these sensors withstand the most demanding processes and measurement requirements.
  • High pressure hot-tap sensor
  • Measurement ranges from 0 ... 1.999 µS/cm to 0 ... 19.99 mS/cm
  • Corrosion resistant 316 stainless steel measurement electrodes
  • Pt100 or Pt1000 integral temperature compensation elements
  • Maximum temperature 200 °C (392 °F)
  • Maximum pressure 2,068 kPa (20,68 bar / 300 psi)
  • Interchangeable and replaceable sensor tips