产品功能:
1、酒精含量数字显示(小单位0.01%BAC & 0.1g/L)
2、测试范围:0.00-0.19% BAC & 0.0-1.9g/L
3、快速响应和恢复
4、报警点可选择
5、自动关机省电功能
6、钥匙扣,易携带
技术参数:
传感器:半导体酒精传感器
预热时间:10秒以内
响应时间:5秒以内
工作环境温度:5 ~ 40摄氏度
测试范围:0.00-0.19% BAC & 0.0-1.9 g/L
电源:使用2x“AAA”碱性电池(机不附带)
产品尺寸:100x31.5x19 毫米
SAT-178 Breath Alcohol Tester
The Breath Alcohol Tester should be used only to give an indication of the possible presence of alcohol in the breath/blood. You should not rely upon it as the sole basis to determine intoxication or whether it is safe to drive a vehicle, operate equipment, or engage in dangerous activities.
Everyone has different body responds to alcohol consumption and his testing result only
As reference, not a subject standard for consequent decision.
The manufacture, importer or distributor takes no responsibility whatsoever for the use of this product for any reason. This product must not be used as a tool for determining whether a person is able to operate a motor vehicle or device legally or safely. The intake of any alcohol will impair reflexes and judgment to operate motor vehicle.
Main Features:
◇ Aadvanced semiconductor oxide alcohol sensor
◇ Quick responseand resume
◇ SMD assembling, stable performance
◇ Smart MCU control
◇ Direct Testing process LCD Indication
◇ Portable design
◇ No touch health design
◇ Audio warning beyond pre-set limit
◇ Battery saved design; Low voltage indication
◇ Mouthpiece optional
How to use the alcohol tester
Warm up
1. Press the power button once, the alcohol tester LCD will turn on with one beep sound.
2. The ”warm up” symbol is displayed, and the 10 to 0 countdown is started that indicate the tester is in warm-up mode.
Note
* If first warm-up is defeated, the tester will be reset automatically and warm up again.
* It always has a large number of gas & impurity adsorbed on the surface of alcohol sensor, when first time taking out the tester from the packaging, or after long time no using for the tester, it need more time for cleaning and warm up the sensor, you should repress the power button and retry several times if possible.
Test
1. The ”Blow” symbol is displayed when warm-up is succeed, and the 10 to 0 countdown is started that indicate the tester is in testing mode.
2. Near and blow into the breath inhaler for 3-5 seconds.
3. Read the test result from the alcohol tester LCD
4. The ”Caution” symbol is displayed if the alcohol concentration is the level:
0.02% BAC(0.2g/l) to 0.05% BAC(0.5g/l).
0.05% BAC(0.5g/l) to 0.08% BAC(0.8g/l).
5. The ”Danger” symbol is displayed with beep audible alert if the alcohol concentration is the level:
over & equal 0.05% BAC(0.5g/l).
over & equal 0.08% BAC(0.8g/l).
Auto power off
1. After the result be display for about 15 seconds, the ”OFF” symbol will appear for 2-3 seconds and the alcohol tester be turned off.
2. If warm-up is defeated, the tester will automatically turned off.
3. If no blow into the breath inhaler at the test mode, the LCD will display ”0.00” value.
Note
To obtain more accurate result, manufacturer recommend you to check repeatedly 2 or 3 times.
Low battery indication
If the ”L” symbol flash on the display, it indicates the batteries electricity is not enough and the tester will automatically turned off, please try to replace the old batteries
Specifications
* Sensor: advanced semiconductor oxide alcohol sensor
* Range: 0.00%-0.19% BAC (0.0-1.9g/l)
* Test accuracy: 0.01% BAC (0.1g/l)
* Power input: 2 X 1.5V ”AAA” alkaline battery
* Operating time: warm up: 10-15s, response: <5s
*Working Environment: -10℃~50℃ ≤95%RH no dews
* Dimension:105mm X 55mm X 17mm @50g
Precaution
-- When after drinking, it is recommended to last after 20 minutes, it is because 20 minutes is approximately for alcohol to be absorbed into blood from the digestive organs, and residual alcohol remaining in the mouth takes this long to dissipate.
-- For accurate result, do not repeat next testing within 3 minutes after last time.
-- Do not smoke and eat for 20 minutes prior testing.
-- Do not use chemicals to clean the tester directly.
-- Do not blowing liquid into the breath pipe.
-- Do not use any excitant substances near the tester, such as pains, insecticides, alcohols.
-- Do not place the tester in the closed environment with contaminated air.
-- The result of this alcohol gives BAC for reference only, manufacturer does not to take any legal responsibility.