TTi EX-R系列数字直流稳压电源
Power, Precision, Simplicity |
Mixed mode with linear final regulation Single, dual and triple output models Current up to 20A, power up to 420W Constant voltage or constant current 4 digit meters with 10mV and 1mA (or 10mA) resolution Switchable remote sense terminals for perfect regulation Silent fan-free cooling (not EX202R/4210R) DC output switch enables voltage/current setup without Safety terminals accept fixed shroud 4mm plugs plus EX354RT has auxiliary output of 1.5V to 5V at 5A |
TECHNICAL SPECIFICATIONS | |
OUTPUT Voltage/Current Ranges
Output Setting & Control Voltage Setting: By coarse and fine controls. Current Setting: By single logarithmic control. Output Mode: Constant voltage or constant current with automatic cross-over. CC indicator in constant current mode. Output Switch: Electronic, non isolating. Preset voltage and current limit displayed when Output off. Output Performance Ripple & Noise: Typically <2mV rms, <10mV pk-pk, (EX355R, EX354RD, EX354RT) CV mode, 20MHz bandwidth Load Regulation: <0.01% of maximum output for a 90% load change (using remote sense). Line Regulation: <0.01% of maximum output for 10% line change. Transient Response: <200us to within 50mV of setting for a 5% to 95% load change. Temp. Coefficient: Voltage: typically <100ppm/oC. Output Protection Output Protection: Outputs will withstand forward voltages up to 40V (EX355R, EX354RD,& EX354RT); 22V (EX1810R); 25V (EX2020R); 48V (EX4210R). Reverse protection by diode clamp for currents to 3A. Output Connections Output Terminals: Universal 4mm safety binding posts on 19mm (0.75") spacing. Terminals can accept fixed shroud 4mm plugs, standard 4mm plugs, fork terminals and bare wires. Remote Sense Sense Selection: Voltage sensing is selected as Local or Remote by front panel switch. Sense Terminals: Sprung loaded screw-less terminals. METER SPECIFICATIONS Display Type: Dual 4-digit meters, 14mm (0.56") LED. Voltage Meter Resolution: 10mV Accuracy: 0.3% of reading +/- 3 digits Current Meter (EX355R, EX354RD, EX354RT) Resolution: 1mA Accuracy: 0.5% of reading +/- 3 digits Current Meter (EX1810R, EX2020R, EX4210R) Resolution: 10mA Accuracy: 0.6% of reading +/- 3 digits AUXILIARY OUTPUT (EX354RT only) Voltage: Variable <1.5V to >5V by front panel control. Meter accuracy: 0.3% +/- 4 digits. Current limit: 5A minimum. Load regulation: <0.5% for 90% load change. Line regulation: <0.1% for 10% line voltage change. Ripple & Noise Typically <2mVrms, <10mVpk-pk (20MHz bandwidth): Output Protection: Output will withstand up to 7V forward voltage. Diode clamp reverse protection for currents up to 3A. Output Terminals: Universal 4mm safety binding posts on 19mm (0.75") spacing. Status Indication: UNREG lamp. GENERAL Input AC Input: EX354RD, EX354RT - 110V to 240V 50/60Hz (universal input); Other Models - 230V AC +/- 10% 50/60Hz; 115V to order.. Installation Category II VA Ratings: EX810R, EX355R - 400VA; EX354RD, EX354RT - 500VA, EX2020R, EX4210R - 800VA Temperature & Environmental Operating Range: +5oC to +40oC, 20% to 80% RH Storage Range: -40oC to + 70oC Environmental: Indoor use at altitudes up to 2000m, Pollution Degree 2. Cooling: EX1810R, EX355R, EX354RD, EX354RT - fan-less convection cooling; EX2020R, EX4210R - fan assisted using low-noise brushless dc fan. Safety & EMC Safety: Complies with EN61010-1 EMC: Complies with EN61326 Physical Size: Single output models - 140x160x320 mm (WxHxD). Dual and triple output models - 260x160x320 mm (WxHxD). Weight: EX810R, EX355R - 3.0kg; EX2020R, EX4210R - 3.6kg; EX354RD, EX354RT - 4.3kg. |
英国TTi
贸易商
全新
英国