KFU8-UFC-EX1.D 特卖
价格:电议
地区:上海市
电 话:138-16754864
手 机:13816754864
传 真:021-60443648

上海卓峙自动化设备有限公司是一家从事工业自动化工程设计、安装、调试、售后服务和代理销售各类进口电气,服务于一体的企业。公司坚持“信誉为本,诚信经营”的理念,依靠网络从事世界传感器,安全栅、隔离栅,电源,低压电器以及气动液压,仪器仪表,机电产品销售与工程配套服务,公司为冶金、石油、化工、钢铁、电力、电子、船舶、汽车、环保、纺织、食品、医疗、制药、包装、等众多行业提供完善的技术方案和备件服务。

特价销售:德国倍加福(P+F),英国MTL安全栅,德国图尔克(TURCK),德国施克(SICK),德国菲尼克斯(PHOENIX),邦纳(BANNER),日本CKD,德国易福门(IFM)等,全系列安全栅,电源,模块,传感器,编码器,端子继电器等,公司备有大量库存,另为客户提供偏门冷门的欧州产品。

联系人:徐工

电话:

QQ:2821445492

  • 1-channel isolated barrier
  • Universal usage at different power supplies
  • Input for NAMUR sensors or dry contacts
  • Input frequency 1 mHz ... 5 kHz
  • Current output 0/4 mA ... 20 mA
  • Relay and transistor output
  • Start-up override
  • Line fault detection (LFD)
  • Up to SIL2 acc. to IEC 61508/IEC 61511
  • 产品阐述
    48 V AC ... 253 V AC/20 V DC ... 90 V DC
    General specifications
    Signal typeDigital Input
    Supply
    Connectionterminals 23, 24
    Rated voltage20 ... 90 V DC / 48 ... 253 V AC 50 ... 60 Hz
    Power loss/power consumption≤ 2 W ; 2.5 VA / 2.2 W ; 3 VA
    Input
    ConnectionInput I: intrinsically safe: terminals 1+, 3-
    Input II: non-intrinsically safe: terminals 13+, 14-
    Input Isensor acc. to EN 60947-5-6 (NAMUR) or mechanical contact
     Pulse duration> 50 μs
     Input frequency0.001 ... 5000 Hz
     Lead monitoringbreakage I ≤ 0.15 mA; short-circuit I > 6.5 mA
    Input IIstartup override: 1 ... 1000 s, adjustable in steps of 1 s
     Active/PassiveI > 4 mA (for min. 100 ms) / I < 1.5 mA
     Open circuit voltage/short-circuit current18 V / 5 mA
    Output
    Connectionoutput I: terminals 10, 11, 12
    output II: terminals 16, 17, 18
    outout III: terminasl 19+, 20-
    output IV: terminals 8+, 7-
    Output I, IIsignal, relay
     Contact loading250 V AC / 2 A / cos φ ≥ 0.7 ; 40 V DC / 2 A
     Mechanical life5 x 107 switching cycles
     Energized/De-energized delayapprox. 20 ms / approx. 20 ms
    Output IIIelectronic output, passive
     Contact loading40 V DC
     Signal level1-signal: (L+) - 2.5 V (50 mA, short-circuit/overload proof)
    0-signal: switched off (off-state current ≤ 10 μA)
    Output IVanalog
     Current range0 ... 20 mA or 4 ... 20 mA
     Open loop voltagemax. 24 V DC
     Loadmax. 650 Ω
     Fault signaldownscale I ≤ 3.6 mA , upscale ≥ 21.5 mA (acc. NAMUR NE43)
    Transfer characteristics
    Output IV 
     Resolution< 10 μA
     Accuracy< 20 μA
     Influence of ambient temperature0.005 %/K (50 ppm)
    Directive conformity
    Electromagnetic compatibility 
     Directive 2004/108/ECEN 61326-1:2006
    Low voltage 
     Directive 2006/95/ECEN 61010-1:2010
    Conformity
    Electromagnetic compatibilityNE 21:2006
    Protection degreeIEC 60529:2001
    Ambient conditions
    Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
    Mechanical specifications
    Protection degreeIP20
    Mass300 g
    Dimensions40 x 119 x 115 mm (1.6 x 4.7 x 4.5 in) , housing type C3
    Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
    Data for application in connection with Ex-areas
    EC-Type Examination CertificateTüV 99 ATEX 1471 , for additional certificates see www.pepperl-fuchs.com
     Group, category, type of protection II (1)GD, I (M1) [Ex ia] IIC, [Ex iaD], [Ex ia] I (-20 °C ≤ Tamb ≤ 60 °C)
    Directive conformity 
     Directive 94/9/ECEN 60079-0:2009, EN 60079-11:2007, EN 60079-26:2007 , EN 61241-11:2006
    International approvals
    FM approval 
     Control drawing16-538FM-12