Click here to view the SlimKIC 2000 datasheet

Profiling So Easy, Anyone Can Do It

By automating the complex task of process set up the SlimKIC® 2000™ makes profiling so easy that any operator can quickly achieve the optimal process. Simply select from a built-in library containing hundreds of commonly used solder paste specifications, and the software automatically defines the process window. Oven zones and mapping of thermocouples on the product are automated using innovative, patent pending technology.

The SlimKIC 2000 simplifies profiling by reducing the process to a single number -- the Process Window Index™ (PWI) -- so you know precisely how good your profile is. The simplified user interface guides the operator through the profiling process, minimizing the potential for improper oven set up and yield-reducing defects.

The Process Window Index

 

Profiling Reduced to a Single Number
For precise ranking of profile performance, the KIC software uses the Process Window Index (PWI). The PWI measures the profile’s fit to the process window in a mathematical and objective manner by using a single number. This aids in optimizing the process by comparing and ranking alternative profiles in terms of their fit to the available process window. The lower the PWI, the more efficient and stable the process! (See the PWI data sheet for a detailed explanation)

Technical Specifications

Accuracy:

±1.2C

Resolution:

Variable 0.3C to 0.1C

Internal Operating Temp:

0C to 105C

Thermocouple Compatibility:

Type K, 9 or 12 channels

Temperature Range:

-150C to 1050C

Power Requirements:

Standard 9V alkaline battery

Thermal Receiver:

433.92 MHz (Dual Unit Model only)

Dimensions:

See Temperature Tolerance Chart below for specifications

Datalogger Model: data is downloaded to the computer through a cable after the run.
Dual Unit Model: data is sent to the computer in real-time during the run. It is also stored internally for high-speed download after the run.

 

Temperature Tolerance Chart

(maximum endurance in minutes at specified temperature)

 

CONFIGURATION

DIMENSIONS (mm)
(Length x Width x Height)

150C

200C

250C

300C

350C

400C

SlimKIC 2000, 9CH no shield

260.4 x 76.2 x 19.9

8.5

5.5

4.2

3.5

  

SlimKIC 2000, 12CH no shield

260.4 x 101.6 x 19.9

8.5

5.5

4.2

3.5

  

LowRider cover

260.4 x 76.2 x 19.9

13.9

8.3

5.5

4.7

  

Thermal Shield 1/8” (3.2mm), 9CH

323.9 x 86.4 x 26.4

17.6

11.0

8.0

6.4

  

Thermal Shield 1/8” (3.2mm), 12CH

323.9 x 108.0 x 26.4

17.6

11.0

8.0

6.4

  

LowRider and Thermal Shield 1/8” (3.2mm)

323.9 x 86.4 x 26.4

22.6

15.1

10.7

8.7

  

Thermal Shield 1/4” (6.4mm), 9CH

330.2 x 95.3 x 34.3

24.6

15.5

11.5

9.8

  

Thermal Shield 1/4” (6.4mm), 12CH

330.2 x 115.6 x 34.3

24.6

15.5

11.5

9.8

  

LowRider and Thermal Shield 1/4” (6.4mm)

330.2 x 95.3 x 34.3

30.7

22.6

16.4

12.2

  

Long Duration Thermal Shield

381.0 x 139.7 x 76.2

62.8

42.2

33.1

29.7

  

Lead-Free Thermal Shield, 9CH

343.9 x 88.9 x 25.4

18.6

12.7

10.7

9.1

7.9

7.6

Lead-Free Thermal Shield, 12CH

343.9 x 109.9 x 25.4

18.6

12.7

10.7

9.1

7.9

7.6

Computer Configuation

Minimum System Requirements

 

1. When KIC 2000 Software is running on the same computer as the Oven software, and/or when additional KIC 2000 Software options are installed, a faster CPU and more RAM may be required. 

2. A USB to Serial Adapter may be required to connect the SlimKIC 2000 for profiling. 

3. Contact KIC for issues with operating systems other than those listed. 

400 MHz Processor, Celeron / 128 Mb RAM1
1 Gb available storage (for product history)
Video 1024 x 768 resolution / 16-bit
1 available serial port or USB port2
1 available parallel port or USB port for software key options
Microsoft® Windows® 2000 or XP3