英国WK6565高频直流偏压源
价格:电议
地区:广东省 深圳市
电 话:0139-22871080
手 机:13922871080
传 真:0755-86652135

英国WK6565高频直流偏压源

 

五種機型且可升級到120MHz

6565B A5A /A 10A : 20Hz to 10MHz

6565B B5A /B 10A : 20Hz to 20MHz

6565B C5A /C 10A : 20Hz to 30MHz

6565B D5A /D 10A : 20Hz to 50MHz

6565B E 5A /E 10A : 20Hz to 120MHz

 

Component tests up to 40A DC bias current

Component inductor tests up to 40A

High accuracy for DC bias current ±1%

Applications: Permits measurement analysis of wound components with levels of DC bias current higher than the standard 200mA for high frequency signals in coils

Control connections: Serial Communication Bus controls application of DC current and monitors status of analyzer. Status data includes excessive voltage drop and over temperature

Optional facilities: 6565B bias units may be paralleled, maximum of four same model units

Interlock: Bias safety interlock socket on rear panel of analyzer provides door lock and closed control lines

 

 

 

 產品規格

 

系列依頻率等級分為:

 

6565B A5A /A 10A : 20Hz to 10MHz

6565B B5A /B 10A : 20Hz to 20MHz

6565B C5A /C 10A : 20Hz to 30MHz

6565B D5A /D 10A : 20Hz to 50MHz

6565B E5A /E 10A : 20Hz to 120MHz

 

Facilities

Output Current 0 to 10A 

Resolution

  From 1mA to 1A in 999 steps of 1mA

From 1.01A to 10A in 899 steps of 10mA 

Dc Bias current accuracy

  ±1% of set bias current ± 1mA from 1mA to 1A

±1% of set bias current ± 10mA from 1.01A to 10A

Accuracy of current drive read back ±1% of set bias current, ±1 digit

Compliance voltage

  9V max at 1V ac drive level*

10V max at 0.25V ac drive level*

Max signal drive level

  1V ac rms 20Hz – 49.9MHz*

0.5V rms 50MHz – 120MHz*

Frequency range 20Hz – 120MHz

Measurement protection modes

  Over-voltage trip, safety interlock, fan failure,

excess temperature and circuit diagnostic checks 

Suitable high current fixtures 1J1026(20A), 1J1027(40A)

Temperature range

Storage  -40°C to 70°C

Operating 0°C to 40°C 

Full accuracy 15°C to 30°C 

Measurement terminals 2-terminals measurement via M8 studs

4-terminal measurement via Kelvin leads and M8 studs

Measurement terminals internally protected by 1.6A fuses against normal inductor back-EMF or accidental disconnection of inductor

Front panel fuses easily replaced

Power input specification

Input supply voltage 85-265V ac rms 47-63Hz via IEC connector

Typical input current 4.2A @ 100-120V, 2.1A @ 220 – 230V

Cooling by 3 internal fans

Mechanical

Case Size (3U) 435mm x 132mm x 522m (W x H x D)

Weight 15kg

*Must be used in conjunction with either a 6500B or 6500P