美国 Magna Power MT系列 可编程直流电源 100KW,站立式机箱
价格:电议
地区:
电 话:86 021 61911916
手 机:13671590819
传 真:86 021 61911916
图文详情
产品属性
相关推荐
IVI驱动程序:多种可视化编程应用可支持
Input
Nominal Voltage 3 phase, 3 wire + ground | 380 VAC (operating range 342 - 418 VAC) 415 VAC (operating range 373 - 456 VAC) 440 VAC (operating range 396 - 484 VAC) 480 VAC (operating range 432 - 528 VAC) |
Frequency | 50 Hz (operating range 45 Hz - 55 Hz) 60 Hz (operating range 54 Hz - 66 Hz) |
Power Factor | > 92% at max. power 100 kW and 150 kW modules > 96% at maximum power 250 kW modules |
Environmental
Operating Temperature | 0°C to 50°C |
Storage Temperature | -25°C to +85°C |
Air Cooling | Front and rear intake, top exhaust |
Physical
Power | Input Phases | Size (H" x W" x D") | Weight |
100 kW 150 kW 250 kW 500 kW 750 kW 1000 kW | 3Φ 3Φ 3Φ 3Φ 3Φ 3Φ | 62.5 x 48 x 31.5 in (158.8 x 121.9 x 80.0 cm) 62.5 x 48 x 31.5 in (158.8 x 121.9 x 80.0 cm) 62.5 x 72 x 31.5 in (158.8 x 182.9 x 80.0 cm) 62.5 x 144 x 31.5 in (158.8 x 365.8 x 80.0 cm) 62.5 x 216 x 31.5 in (158.8 x 548.7 x 80.0 cm) 62.5 x 288 x 31.5 in (158.8 x 731.6 x 80.0 cm) | 1600 lbs (725.8 kg) 2100 lbs (952.5 kg) 3300 lbs (1496.9 kg) 6600 lbs (2993.7 kg) 9900 lbs (4490.6 kg) 13200 lbs (5987.4 kg) |
Output
Ripple | See Model Charts |
Line Regulation | Voltage Mode: ± 0.004% of full scale Current Mode: ± 0.02% of full scale |
Load Regulation | Voltage Mode: ± 0.01% of full scale Current Mode: ± 0.04% of full scale |
Load Transient Response | 2 ms to recover within ±1% of regulated output with a 50% to 100% or 100% to 50% step load change |
Efficiency | ≥ 90%; See Model Charts |
Stability | ± 0.10% for 8 hrs. after 30 min. warmup |
Isolation | User inputs and outputs: referenced to Earth ground Maximum input voltage to ground: ±2500 Vac Maximum output voltage to ground: ±1000 Vdc for models less than or equal to 1000 Vdc, ±4000 Vdc for models greater than 1000 Vdc. |
Maximum Slew Rate | Standard Models: 100 ms for an output voltage change from 0 to 63%, 100 ms for an output current change from 0 to 63%. With High Slew Rate Option (+HS): 6 ms for an output voltage change from 0 to 63%, 12 ms for an output current change from 0 to 63%. |
Bandwidth | Standard Models: 3 Hz with remote analog voltage programming, 2 Hz with remote analog current programming. With High Slew Rate Option (+HS): 60 Hz with remote analog voltage programming, 45 Hz with remote analog current programming. |
Programming Levels and Accuracy of Full Scale
Voltage Set Point | Current Set Point | OVT Set Point | OCT Set Point | |
Remote Analog Programming Accuracy | ± 0.075% | ± 0.075% | ± 0.075% | ± 0.075% |
Digital Programming Accuracy | ± 0.075% | ± 0.075% | ± 0.075% | ± 0.075% |
Remote Analog Programming Levels | 0 - 10.0 Vdc | 0 - 10.0 Vdc | 0 - 10.0 Vdc | 0 - 10.0 Vdc |
Monitoring Levels and Accuracy of Full Scale
Output Voltage | Output Current | |
Remote Analog Monitoring Accuracy | ± 0.2% | ± 0.2% |
Digital Monitoring Accuracy | ± 0.2% | ± 0.2% |
Remote Analog Monitoring Levels | 0 - 10.0 V | 0 - 10.0 V |
Control Limits
Remote Sense Limits | 3% maximum voltage drop from output terminals to load. Remote sense is not available for models with output voltages greater than 1000 Vdc. |
Period Programming Limits | Minimum period: 10 msec Maximum Period: 9997 sec or 2.77 hours |
Digital control inputs and outputs limits | Input voltage: 0 to 5 Vdc, 10K input impedance; Output voltage: 0 to 5 Vdc, 5 mA drive capacity 5 V supply: 25 mA. |