交流耐压测试仪
价格:电议
地区:广东省 东莞市
电 话:0769-82307098
手 机:13790240876
传 真:0769-82307098
图文详情
产品属性
相关推荐
● 技术参数 | ||||||||||
MODEL | 7110 | 7112 | 7120 | 7122 | ||||||
AC WITHSTAND VOLTAGE | ||||||||||
Output Rating | 5KVAC/12mA | |||||||||
Range | Resolution | Accuracy | ||||||||
Output Voltage,KVAC | 0-5.00 | 0.01 | ±( 2% of setting +5V ) | |||||||
Output Frequency | 50Hz/60Hz±100ppm,User Selection | |||||||||
Output Waveform | Sine Wave,THD<2%( Resistion Load ),Crest Factor = 1.3-1.5 | |||||||||
Output Regulation | ±( 1% of output +5V ),Form no load full load | |||||||||
SETTINGS | ||||||||||
Hi-Limit AC Current,mA | 0.10-12.00 | 0.01 | ±( 2% of setting +2counts ) | |||||||
Lo-Limit AC Current,mA | 0.00-12.00 | 0.01 | ±( 2% of setting +2counts ) | |||||||
Ramp Time,second | 0.1-999.9 | 0.1 | ±( 0.1% + 0.05sec ) | |||||||
Dwell Time,second | 0,0.2-999.9 | 0.1 | ||||||||
( 0=continuous ) | ||||||||||
Arc Detection | 0,1-9 ranges ( 0=OFF,9 is the most sensitivity ) | |||||||||
DC WITHSTAND VOLTAGE(7120,7122 ONLY) | ||||||||||
Output Rating | 6KVDC/5mA | |||||||||
Output Voltage,KVDC | 0-6.00 | 0.01 | ±( 2% of setting +5V ) | |||||||
Output Ripple | < 5% ( 6KV/5mA at Resistive Load ) | |||||||||
SETTINGS | ||||||||||
Hi-Limit DC Current,mA | 0.02-5.00 | 0.01 | ±( 2% of setting +2counts ) | |||||||
Lo-Limit DC Current,mA | 0.00-5.00 | 0.01 | ±( 2% of setting +2counts ) | |||||||
Ramp Time,second | 0.1-999.9 | 0.1 | ±( 0.1% + 0.05sec ) | |||||||
Dwell Time,second | 0,0.2-999.9 | 0.1 | ||||||||
( 0=continuous ) | ||||||||||
Arc Detection | 0,1-9 ranges ( 0=OFF,9 is the most sensitivity ) | |||||||||
Discharge Time | ≦200msec | |||||||||
7110/7112/7120/7122实用数位合成型耐压/绝缘测试仪 | ||||||||||
MODEL | 7110 | 7112 | 7120 | 7122 | ||||||
INSULATION RESISTANCE ( 7112,7122 ONLY ) | ||||||||||
Output Rating | 1KVDC/1000MW | |||||||||
Output Voltage,KVDC | 0.10-1.00 | 0.01 | ±( 2% of setting +3V ) | |||||||
SETTINGS | ||||||||||
Hi-Limit Resistance,MW | 0,1-1000(0=OFF ) | 1 | ±( 3% of setting +2counts ) at ≧ 500VDC | |||||||
Lo-Limit Resistance,MW | 1-1000 | 1 | ±( 7% of setting +2counts ) at <500VDC | |||||||
Delay Time,second | 0,0.5-999.9 | 0.1 | ± ( 0.1% + 0.05sec ) | |||||||
( 0=continuous ) | ||||||||||
GENERAL | ||||||||||
Input Voltage AC | 115/230VAC±15%,50/60Hz±5%,Fuse 3.15A Fast | |||||||||
PLC Remote Control | Input: Test,Reset | |||||||||
Output: Pass,Fail,Processing | ||||||||||
Memory | 5 Sets store/Recall of each Memory,4Test Mode Selectable ( W,I,W-I,I-W Only 7112,7122) | |||||||||
Display | 16×2 LCD with back light | |||||||||
Key Lock | To prevent unauthorized alteration of test parameters | |||||||||
Calibration | Build-in software and external calibrated meters | |||||||||
Environment | 0-40℃,20-80%RH | |||||||||
Dimension/Net Weight | 280mm(W)×89mm(H)×370mm(D)/9Kg | |||||||||
※Ordering Information※--------------------------------------------------------------------------------- | ||||||||||
7110 AC Withstand Voltage Tester | ||||||||||
7112 AC Withstand Voltage / Insulation Resistance Tester | ||||||||||
7120 AC/DC Withstand Voltage Tester | ||||||||||
7122 AC/DC Withstand Voltage / Insulation Resistance Tester |