供台湾华仪 7126耐压,绝缘,接地综合安规测试仪
价格:电议
地区:江苏省
电 话:86 0510 82622108
手 机:13915334616
传 真:86 0510 82607385
图文详情
产品属性
相关推荐
类型 | 台湾华仪 7126耐压,绝缘,接地综合安规测试仪 | 品牌 | 台湾华仪 7126耐压,绝缘,接地综合安规测试仪 |
型号 | 台湾华仪 7126耐压,绝缘,接地综合安规测试仪 | 测量范围 | . |
测量 | . | 电源电压 | .(V) |
尺寸 | .(mm) | 用途 | . |
详细介绍
特点:
微电脑数字式设计,软件式参数设定,人性化操作
电压缓升功能,符合国际安规要求
多种项目测试,一键轻松完成
可选择50/60Hz测试
测试记忆组功能
PLC遥控功能
选购信息
编号7126综合安规测试仪-产品及附件
7126ACW/DCW/IR/GBTester
INPUT | ||
Voltage | 115/230 VAC ± 10%, User selection | |
Frequency | 50/60 Hz ± 5% | |
Fuse | 6.3 Amp 250V Slo-Blo | |
DIELECTRIC WITHSTAND TEST MODE | ||
Output Rating | 5 KV @ 20mA AC | |
6 KV @ 5 mA DC | ||
Output Adjustment | Range: | 0-5 KV AC, 0-6 KV DC |
Resolution: | 10 volt/step | |
Accuracy: | ± (2% of setting + 5 volts) | |
Voltage Display | Range: | 0 - 5 KVAC / 0-6KV DC |
Resolution: | 10 volt/step | |
Accuracy: | ± (2% of reading + 10 volts) | |
HI / LO -Limit AC | Range: | 0.00 - 20.00 mA |
Resolution: | 0.01 mA/step | |
Accuracy: | ± (2% of setting + 0.02 mA) | |
AC Current Display | Range: | 0.00 - 20.00 mA |
Resolution: | 0.01 mA/step | |
Accuracy: | ± (2% of reading + 0.02 mA) | |
HI / LO -Limit DC | Range: | 0.00 - 5.00 mA |
Resolution: | 0.01 mA/step | |
Accuracy: | ± (2% of setting + 0.02 mA) | |
DC Current Display | Range: | 0.00 - 5.00 mA |
Resolution: | 0.01 mA/step | |
Accuracy: | ± (2% of reading + 0.02 mA) | |
Failure Detector | Audible and Visual | |
Output Ripple | < 5% (6KVDC/5 mA at Resistive Load) | |
Discharge Time | ≦ 200 ms | |
Maximum Capacitive Load in DC Mode | 1µF < 1KV , 0.75µF < 2KV, 0.5µF < 3KV, 0.08µF < 4KV, 0.04µF < 5KV, 0.01µF < 6KV | |
AC Wave Form | Sine wave Distortion : < 2% THD ; Crest Factor= 1.3 – 1.5 | |
Output Frequency | Range: | 60 or 50 Hz, User Selection |
Output Regulation | ± (1 % of output + 5 volts) from no load to full load | |
Dwell Timer | Range: | 0, 0.2 - 999.9 sec, (0 = Constant) |
Resolution: | 0.1 sec increments | |
Accuracy: | ± (0.1% + 0.05 sec) | |
Ramp Timer | Range: | 0.1 - 999.9 sec |
Resolution: | 0.1 sec increments | |
Accuracy | ± (0.1% + 0.05 sec) | |
INSULATION RESISTANCE TEST MODE | ||
Output Voltage | Range: | 100 - 1000 Volts DC |
Resolution: | 1 volt/step | |
Accuracy: | ± (2% of reading + 5 volts) | |
Voltage Display | Range: | 0 - 1000 V |
Resolution: | 1 volt/step | |
Accuracy: | ± (2% of reading + 2 counts) | |
Resistance Display | Range: | 1 - 1000 MΩ (4 Digit, Auto Ranging) |
Resolution: | 0.01/0.1 MΩ | |
Accuracy: | ± (3% of reading + 2 counts) at test voltage > 500V | |
± (7% of reading +2 counts) at test voltage < 500V | ||
HI-Limit | Range: | 0, 1 - 1000 M Ω (0 = Off) |
LO-Limit | Range: | 1 - 1000 M Ω |
Delay Timer | Range: | 0, 0.5 - 999.9 sec (0 = Constant) |
Resolution: | 0.1 sec/step | |
Accuracy: | ± (0.1% + 0.05 sec) | |
GROUND BOND TEST MODE | ||
Output Voltage | Range: | AC 6 volts Max. |
Output Frequency | Range: | 60 or 50 Hz, User Selection |
Accuracy: | ±0.1% | |
Output Current | Range: | 3.0 - 30.0 Amps AC |
Resolution: | 0.1 Amp/step | |
Accuracy : | ± (2 % of setting + 0.1A) | |
Current Display | Range: | 0.0 - 30.0 Amps |
Resolution: | 0.1 Amp/step | |
Accuracy: | ± (3 % of reading + 0.1A) | |
Resistance HI-Limit | Range: | 0 - 510 mΩ |
Resistance Display | Range: | 0 – 510 mΩ for 0.0 – 10.0 Amps |
0 – 200 mΩ for 10.1 – 25.0 Amps | ||
0 – 150 mΩ for 25.1 – 30.0 Amps | ||
Resolution: | 1 mΩ/step | |
Accuracy: | ± (2 % of Setting + 2 mΩ ) | |
Dwell Timer | Range: | 0, 0.5 - 999.9 sec (0 = Constant) |
Resolution: | 0.1 sec/step | |
Accuracy: | ± (0.1% + 0.05 sec) | |
Lead Resistance Offset | Max. Offset Capability: | 100 mΩ |
Resolution: | 1 mΩ / step | |
Accuracy: | ± (2 % of Setting + 2 mΩ ) | |
GENERAL SPECIFICATIONS | ||
PLC Remote Control | Input - Test, Reset, Interlock & Recall Memory 1 - 6 | |
Output - Pass, Fail, Test-in-Process | ||
Memory | Allows storage of up to 6 different test programs and 6 step/each memory and single step mode. | |
Security | Lockout capability to avoid unauthorized access to test set-up programs. | |
Calibration | Software and adjustments are made through front panel. | |
Mechanical | Bench or rack mount with tilt up front feet. | |
Optional Arc Detection Hardware | ACW and DCW; Software adjustable Arc Level 0-9 | |
Dimension | 280(W) x 89(H) x 430(D) mm | |
Weight | 33 lbs. (15 kg) |