Specifications(15℃~35℃,RH≤75%) |
Model | 510B |
Resistance Measure | 0~150.0mΩ |
Accuracy | ±2%±3 count of full scale (1~30A) |
Test Current Output | 1~30A AC constant current adjusted Max Current 30A AC Max Voltage 6V |
Output Ammeter | Digital display |
Scale | 0~30A AC(±1% ?3 counts of full scale) |
GO/NG Judgment |
Judgment | Judged NG when measure value is greater than reference value, followed by NG alarm output and output cutoff Judged GO if there are no abnormalities after the set amount of time has passed, followed by GO signal output |
Reference Value |
Setting Range | Randomly set between 5~100% of the measuring range |
Judgment Accuracy | ?5% of full scale with respect to reference value 1~5A ±3% of full scale with respect to reference value 5~30A |
Offset Function | Allows to preset a short circuit resistance value and makes a GO/NG judgment by comparing with the reference value after subtracting the short circuit resistance value. |
Offset Range | Up to 100mΩ |
Test Duration | 0.5 seconds to 10 minutes |
Remote Control |
Start/stop | Low active control |
Operation | Input Conditions High level input voltage:11~15V,Low level input voltage:0~4V,Low level input current :Max.2mA Pulse width: Min.20ms |
Test Frequency | 50Hz,60Hz |
Signal Output | Test, GO, NG, Warning, Ready, Monitor |
Accessories | Test Cable |
Power Requirement | 110/220V±10%,50/60Hz |
Dimensions | 460(W)×420(D)×200(H)mm |
Weight | Approx. 18.5Kg |