品牌 | anseros | 型号 | mp |
类型 | 泵吸式臭氧检测仪 | 测量范围 | 0-2000mg/m3 |
测量对象 | ozone | 测量 | 0.2% |
电源 | 220vac |
臭氧检测仪MP,臭氧分析仪,臭氧水检测仪,高浓度臭氧检测仪,低浓度臭氧检测仪,高臭氧分析仪,进口臭氧检测仪,世界臭氧检测仪ANSEROS COMPANY
Anseros UV ozone analyzer for measurement of ozone in air or oxygen at low concentrations
Continuous processUV ozone analyzer for measurement of ozone in air or oxygen at low concentrations.
德国进口低浓度臭氧检测仪
德国进口高臭氧气体检测仪
德国进口臭氧分析仪维修中心
CONTINUOUS PROCESS UV OZONE ANALYSER FOR MEASUREMENT
OF OZONE IN AIR AT HIGH AND LOW CONCENTRATION
PLEASE MR. WANG E-MAI;
低浓度臭氧分析仪 技术参数:
检测范围:(MP6060 )0~2.000 0~20.00 0~200.0 mg O3/Nm3
(MP6020 ) 0~2000 mg O3/Nm3
检测:0.2
重 现 性:±0.2%
输 出:0-20mA,串行接口
零点偏移:0%(自动校零)
量程偏移:0%(微处理器控制)
电 源:220VAC 50Hz
可选显示单位:ppm, mgO3/m3, mgO3/Nm3, ppm (V/V) , pphm, pphm (V/V)
压力补偿:自动
温度补偿:自动
气体压力:连续
外形尺寸:H135×W485×D365
重 量:10Kg
保 质 期:12个月
ANSEROS MP OZONE ANALYZER 0-100PPM,0-2G/M3
● BUILT-IN ALARMS ● MICROPROCESSOR CONTROLLED ● MINIMUM DETECTABLE LEVELS UNDER 1ppb ● UNIQUE TECHNOLOGY: NO SWITCHING VALVES AND ONLY A SINGLE UV BEAM IS USED ● NO CALIBRATION NECESSARY (PRESET AT MANUFACTURE) ● CUSTOM ENGINEERED ABSORPTION CELL FOU REQUIRED APPLICATION ● ERROR FREE DATA ENSURED BY A CONTINUOUS FLOW OF THE SAMPLE THROUGH THE ANALYSER ● DIGITAL OUTPUT SIGNALS: OZONE LEVEL, GAS PRESSURE, GAS TEMPERATURE ● INTERNAL OZONE GENERATOR (OPTIONAL) ● CONFIRMS THE FOLLOWING STANDARDS: EPA, ISO, IOA, DIN,NFT |
ACCURATE MONITORING OF LOW AND HIGH OZONE CONCENTRATIONS IN GAS |
MEDICAL, ODOUR REMOVAL, ENVIRONMENTAL, INDUSTRIAL SAFETY/HYGIENE, R&D/MATERIAL TESTING, CALIBRATION OF OTHER OZONE MONITORS |
PRINCIPLE OF OPERATION |
SPECIFICATIONS |
NON-DISPERSIVE ULTRA-VIOLET ABSORPTION (LAMBERT-BEER); ADMITTED OPTICAL SYSTEM | EXAMPLES OF POSSIBLE UNITS DISPLAYED: ppm,mgO3/Nm3,gO3/Nm3,%WEIGHT |
RANGE:0~1.000, 0~10.00, 0~100.0ppm 0~1.000, 0~10.00, 0~100.0, 0~200.0 gO3/Nm3 (OTHERS ON REQUEST) | PRESSURE COMPENSATION:AUTOMATIC |
TEMPERATURE COMPENSATION AUTOMATIC | |
REPEATABILITY: ± 0.2% OF SCALE END | RATE OF MEASUREMENT: EVERY 2 SECONDS |
ACCURACY: ±2% OF READING | DIGITAL OUTPUTS: RS232、IEEE、V24(OZONE LEVEL, PRESSURE, TEMP) |
DETECTION LIMIT: 10ppb | ANALOGUE OUTPUTS: CUSTOMIZED SPECIFICATION |
ZERO DRIFT: 0%(AUTOMATIC ZERO) | REQUIRED FLOW RATE: 100~200l/h |
SPAN DRIFT: 0%(MICROPROCESSOR CONTROLLED) | WEIGHT: 10kg |
SIZE::STANDARD 19INCH CABINET MOUNT, 3HU (mm) H135×W485×D365 (inch) H5.3” ×W18.9”×D14.2” | GAS PRESSURE: CONTINUOUS |
EXTERNAL POWER SUPPLY:110V/230V, 50~60Hz | POWER SUPPLY: INTERNAL/EXTERNAL110V/230V50~60Hz |
OUTPUT: 0/4~20mA或0~1VDCRS32 SERIAL INTERFACE (OPTIONAL) |
ANSEROS GM-PRO 0--200G/M3 0.2%
ANSEROS WP 0--200PPM, 0---200G/M3
ANSEROS GM-6000-OEM 0-300G/M3 1%
ANSEROS SEN6060 0-1PPM
ANSEROS SEN-K,SEN-P 0-1PPM