品牌 | R/S | 型号 | CTS60 |
用途 | DECT测试 |
·DECT电话(手提式和固定式)
·通过软键进行菜单控制
·TFT彩色显示
·菜单有6种语言
·紧缩式、坚固的设计,重量轻
·动态范围: DECT>60dB
·内置草靠示波器TCXO或OCXO
·GSM和DECT的RF输入/输出合并
·通过附加的输入/输出的DECT断线测量
·通过RS232-C实现远控测量
·内置草靠示波器TCXO或OCXO
·通过RS232-C实现远控测量
技术指标
·GSM signal generator
Built-in reference oscillator | standard |
Frequency drift in temperature range +5℃to 40℃ | ≤1*10^-6 |
Aging | ≤0.5*10^-6/yearat 35℃ |
GSM |
Frequency range | GSM900 band | 935MHz to 960 MHz |
GSM1800 band | 1805MHz to 1880 MHz | |
GSM 1900 band | 1930MHzto 1990 MHz | |
Resolution | GSMchannel spacing 200 kHz | |
Outputlevel | ||
RFIN/OUT with 0 dB ext.attenuation | -50dBm to -110 dBm | |
RF OUT2 GSM with 0 dB ext.attneuation | -15dBmto -75dBm | |
Level error | RF IN/OUT | ≤1.5dBm |
RF OUT2 GSM | ≤2.0dBm | |
Modulation | GMSK,BxT=0.3 | |
Norrowband Spectoum Monitor Option CTS-B7 | ||
Span | 300kHz | |
Resolutionbandwidth | 4/10/20/50/100kHz | |
Dynamic range | (p>5dBm) | |
Δf=0kHz to 30 kHz | typ:35dBc | |
Δf=30kHz to 150 kHz | typ:50dBc | |
Morkers | 3marders and delta-marker | |
GSM peak power meter | ||
Frequency range | GSM900band | 890 MHz to 915 MHz |
GSM1800band | 1710MHz to 1785 MHz | |
GSM1900 band | 1850MHzto 1910 MHz | |
Level range | -15dBmto 39 dBm(peak values up to 41 dBm) | |
GSMmeasurement of phase and frequency error | ||
Frequencyrange | GSM900 band | 890 MHz to 915 MHz |
GSM1800 band | 1710MHzto 1785 MHz | |
GSM1900 band | 1850MHzto 1910 MHz | |
Reference level forfull dynamic range with 0 dB ext. | ||
attenuation | 0dBm to +39(pead values up to 41 dBm) | |
Dynamicrange (p>5 dBm) | ≥55dB | |
Resolution | 0.1dB | |
DECT | ||
DECT signal generator | ||
Frequency range | 1876.608MHzto 1935.360 MHz and half channels | |
Frequency drift | somean reference oscillator | |
Outputlevel | ||
RFIN/OUT | -100 dBm to -40dBm | |
RF OUT2 DECT | (-20 dBm to dBm if RF IN2DECTis active) useable up to 5 dBm | |
Level error | ≤1.5dB | |
RF IN/OUT | ≤2.0dB | |
RF OUT2 DECT | GFSK(BxT=0.5) | |
DECT analyzer | ||
Frequency range | some as signal generator | |
Measurement range | with0 dB external attenuation | |
RF IN/OUT | 30dBm to -30dBm | |
RF IN2 DECT | -35dBmto -55dBm | |
FM demodulator | ||
Frequency range | 0kHzto 450kHz | |
Resolution | 4kHz | |
DC offset | <3kHz | |
Residual FM | ||
RFIN/OUT | <15kHz,peak,95% confidencre | |
(30dBm to 5 dBm) | ||
<5kHz,peak,95% confidencre | ||
(30dBm to 15dBm) | ||
RF IN2 DECT | <15kHz,peak,95% confidencre | |
(-35 dBmto 15dBm) | ||
<15kHz,peak,95% confidencre | ||
(-35dBmto -40 dBm) | ||
Level meter | ||
Range | ||
RFIN/OUT | 30dBm to -30dBm | |
RFIN2 DECT | -35dBm to -55 dBm | |
Dynamicrange | ≥60dB (for p=24dBm) | |
Resolution | 0.5dB | |
Accuracy | ||
RF IN/OUT | <1dB+resolution(30dBm to 5 dBm) | |
<2dB+resolution(<5dBm) | ||
RF IN2 DECT | <2dB+resolution | |
(-35dBmto -51dBm) | ||
<2.5dB+resolution(<-51dBm) | ||
Audion interface | ||
Output | unbalanced | |
Range | 558mV,300Hz to 3kHz | |
Outputimpedance | <10Ω(RL>2kΩ) | |
S/N+THD | 30dBat max.level | |
Passband ripple | 0.5dB | |
DECT applications | averaging10 bursts | |
Modulation section1,2,4 | ||
Error | approx.11kHz with min.(202kHz) permissible deviation approx.13 kHz with max.(403kHz) permissible deviation | |
Frequency drift | ||
Error | appox.1kHz/ms(over200 bursts) | |
Transmit powr | ||
Measurement accurocy | ||
RF IN/OUT | <1dB+resolution(30dBm to5 dBm) | |
<2dB+resolution(<5dBm) | ||
RF IN2 DECT | <2dB+resloution | |
(-35dBm to -51 dBm) | ||
<2.5 dB+resolution(<51 dBm) |