品牌R/S型号CMD80
测量范围CDMA US/PCS/TDMA电源电压AC220(V)
尺寸500(mm) 重量20(kg)
用途CDMA通讯产品性能试测
  • 详细说明

    CMD80是种能够对CDMA AMPS D-AMPS(TDMA)和TACS等各种类型移动站进行测量的测试仪器。在进行射频参数测量时,它可仿真移动站的真实工作环境,如模拟为三模式/双频段基站与移动站建立通话并在DUT处于正常通话状态下(非专门测试模式)时进行各项测量仪器可支持下列网络和频率波段:高测量速度以及远程控制功能,(通过 IEC/IEEE总线)CMD80使得测试仪适于在生产测试中使用仪器的高测量更是用于移动站开发研制所必需的特性。

    CMD80技术指标
    Signalgenerator
    Frequency range, US Cellular 869MHz to 894MHz
    Powermeasurement(feference level range)
    RF IN/OUT (fullscale) +41 dBm to -28 dBm
    RF IN2 (fullscale) 0 dBm to -69 dBm
    Dynamic range 50dB below reference level
    Demodulator O-QPSK
    Modulation measurements signal quality(p)
      phase error
      magnitudeerror
      error vector amplitued
      carrier feedthraough
      I/Qimbalance
      cqrrier frequency error
      transmission error
    DCvoltoge measuremints Range 0 V to ±30V
    DCcurrent measurements Range 0 A to ±10A
    SignallingDigital modes 1595,UB-IS95,J-STD008,T53
    D-AMPS;optionCMD-B84    
      RF OUT2 +3 dBm to -112dBm
    Modulation π/4DQPSK or unmodulated
    Analyzer  
    Powermeasurement(referene level range)  
    RF IN/OUT(fullscale) +39dBm to -60 dBm
    RF IN2(full scale) -2dBm to -100 dBm
    Power ramp  
    Adjacent-channel power  
    Modulationmeasurements phase error
      magnitudeerror
      error vector amplitued
      carrier feedthraough
      I/Qimbalance
      cqrrier frequency error
    Bit error rate measurement  
    SignallingDigital modes IS 136,IS54
    RF signal generator  
    Frequency range  
    AMPS 869MHz to 894MHz
    N-AMPS 869 MHz to 894MHz
    TACS 935 MHz to 960MHz
    J-TACS 860MHz to 870MHz
    E-TACS 917 MHz to 950MHz
    N-TACS 843 MHz to 846MHz
      863.5MHzto 867MHz
    Output level  
    RF IN/OUT -20 dBm to -124 dBm
    RFIN2 0 dBm to -105 dBm
    FM modulation  
    RF analyzer  
    Frequencyrange  
    AMPS 824 MHz to 849 MHz
    N-AMPS 824 MHz to 849 MHz 
    TACS 890MHz to 915 MHz
    J-TACS 915 MHz to 925 MHz
    E-TACS 872 MHz to 905 MHz 
    N-TACS 898 MHz to 901 MHz 
      918.5MHz to 922 MHz
    Referenec level  
    RF IN/OUT 0 dBm to +41 dBm
    RFIN2 0 dBm to -69 dBm
    FM demodulation  
    Signaling analog signalling AMPS(IS95)
      NAMPS,TACSMJ/E/N-TACS
    Audiosource  
    Frequency 50 Hz to 4kHz(single tone)
    Output voltage Range 0.1mVto 5V,rms
    AF analyzer  
    Measurements frequency
      AC voltage
      THD