品牌 | wk | 型号 | 3261AAB |
测量范围 | 20 Hz to 3 MHz | 测量 | 0.1% |
电源电压 | 1 mV to 10 V(V) | 尺寸 | 150*440*520(mm) |
重量 | 14(kg) | 用途 | 通讯变压器测试仪 |
3261AAB是透过单一治具,针对通信变压器的自动测试仪,搭配3260B精密磁性元件分析仪使用,能量测插损(IL)及回损(RL)、纵向平衡及横向平衡、总谐波失真(THD)这些参数能透过3260B精密磁性元件分析仪的图形选配功能(/G graph option)绘制图形并可列印输出。
Telecom Unit - 3261A
Automatically tests telecom transformers in a
production environment
Measures Total Harmonic Distortion, longitudinal
and transverse balance and Insertion Loss and
Return Loss
Fast, accurate and repeatable automatic
measurements
Straightforward intuitive operation
Graph longitudinal and transverse balance, and
insertion and return loss against frequency
Suitable for ADSL, HDSL, ISDN, analog line
matching transformers and POTS splitters
Accurate DC bias current
Low cost compared to comparable equipment
Telecom component characterisation
3261A Telecom Unit forms the core of a comprehensive
component test system. It is configured in conjunction with
the Wayne Kerr 3260B Precision Magnetics Analyzer to
carry out a wide variety of telecom-related measurements.
Telecoms Fixture model 1008 further enhances the test
capability by providing an interface to connect units under
test such as transformers.
Complete telecom transformer
characterization
Automatic production testing of telecom transformers
is available with the 3261A. Transformers are
characterized at the press of a button.
Total Harmonic Distortion
Providing unrivalled Total Harmonic Distortion (THD)
performance this optional function displays the second,
third, fourth and fifth harmonic as well as THD.
Measurements as low as -110 dB can be carried out;
the user can set a large number of preset fundamental
frequencies from 150 Hz to 200 kHz.
Longitudinal balance and transverse
balance
This optional function provides longitudinal balance
and transverse balance measurements in line with
IEEE 455, ITU recommendation O.9 (O.121) and FCC
68.310 over the frequency range 200 Hz to 3 MHz.
Measurement capability is high, longitudinal balance
accuracy is ±1 dB over 80 dB, ensuring that devices
can be measured with confidence.
The longitudinal and transverse balance of any
component can be completely characterized
graphically across the full frequency band enabling
component performance to be analyzed in more detail
Insertion Loss and Return Loss
3261A Telecom Unit measures Insertion Loss and Return
Loss from 20 Hz to 3 MHz on transformers and POTS
splitters.
The instrument can also measure and display many
parameters including Insertion Loss and Return Loss
against frequency in a graphical form - ideal in a design or
development environment.
Swept measurements in graphical form
It is often important to characterize component
performance outside its operating range, especially during
component design. The 3261A allows Insertion Loss,
Return Loss, transverse and longitudinal balance, and the
usual basic transformer parameters, such as Inductance
and interwinding capacitance, to be displayed graphically.
Sweeping the full frequency band for the particular
measurement the user can identify the maximum and
minimum point on the graph and a moveable marker
displays the frequency and level. The graph axes can
be selected as either a logarithmic or linear scale.
Comprehensive test system
The key to the test system’s versatility and accuracy is
the combination of a precision impedance analyzer
with a dedicated telecomms test unit. This
combination provides many advantages.
Where special interface methods are needed the 1008
Telecoms Fixture is available, or customised fixtures
can be configured using a blank fixture to ensure high
integrity measurements.
3261A Telecom Unit is the core of a comprehensive test system which also incorporates
3260B Precision Magnetics Analyzer and Telecoms Fixture model 1008
ADSL, ISDN and HDSL analogue line matching
transformers and POTS splitters
ADSL technology requires tighter specifications and
additional measurements when testing line matching
transformers. The 3261A provides all the required
measurements and performance for ADSL technology,
including Total Harmonic Distortion, longitudinal and
transverse balance, Insertion Loss and Return Loss.
It not only exceeds the required specifications but also
makes all the measurements automatically from the same
fixture. For the user it is just a case of connect and test,
ideal in a production environment, with no complex setups,
special jigs or the need to calculate the result from a
number of voltage measurements - the 3261A does it all.
The user is able to select the required line side
termination from a list of predetermined values.
Equipment side terminations are provided by the user
and can be connected to the appropriate socket on the
3261A. Once the termination has been fitted no
further interaction is required by the user.
Accurate DC bias current
DC bias current can be selected for Insertion Loss,
Return Loss and Total Harmonic Distortion.
This function provides high accuracy user selectable
DC current in the range 1 mA to 200 mA in 0.1 mA
steps (to 20 mA) and 1 mA steps (to 200 mA).
The total production test solution ... in a single fixture
Replacing many discrete instruments, complex jigs and
difficult measurements, the 3261A Telecom Unit provides
all the functions needed to meet the new telecom
standards in a single multi-function unit.
It also replaces all the hard work, high skill levels and
uncertainty of manual testing by handling all the complexity
internally and presenting the user with the information
required quickly and accurately. In a production
environment it is just a case of connect and test.
All the user has to do is press the start button and the
3261A Telecom Unit makes all the measurements and
displays a Pass/Fail banner.
Technical specifications
Telecom Unit – 3261A
General
Line side termination: 50, 75, 100, 120, 135, 600, 900 Ω
Equipment side termination: Customer is required to supply
centre tapped 1% resistor
Insertion Loss
Drive level*: -65 dBm to +20 dBm
Drive level units: dBm, dBμV, V
Frequency range: 20 Hz to 3 MHz
Basic Accuracy**: 0 to -3 dB ±0.1 dB
*Varies with line impedance
**Varies with frequency
Return Loss
Drive level*: -60 dBm to +25dBm
Drive level units: dBm, dBμV, V
Frequency range: 20 Hz to 3 MHz
Basic Accuracy**: 0 to 25 dB ±1dB
25 to 30 dB ±2 dB
30 to 35 dB ±3 dB
*Varies with DUT impedance
**Varies with frequency
Transverse balance (analogue voiceband)
Drive level: 0 dBm (0.775 V rms)
Frequency range: 200 Hz to 10 kHz
Basic Accuracy: to 80 dB ±1 dB
Transverse balance (digital)
Drive level: 0 dBm (0.316 V rms)
Frequency range: 10 kHz to 3 MHz
Basic Accuracy:
to 55 dB ±1dB (≤1.55 MHz)
to 45 dB ±1dB (>1.55 MHz)
45 dB to 55 dB ±3 dB (>1.55 MHz)
Longitudinal balance
(analogue voiceband)
Drive level: 1 V rms
Frequency range: 200 Hz to 10 kHz
Basic accuracy: to 80 dB ±1 dB
Longitudinal balance (digital)
Drive Level: 0 dBm
FrequencyRange: 10 kHz to 3 MHz
Basic Accuracy:
to 55 dB ±1 dB (10 kHz to 1.1 MHz)
to 45 dB ±1 dB (>1.1 MHz)
45 dB to 55 dB ±3 dB (>1.1 MHz)
Total Harmonic Distortion
Maximum drive level: 6 V rms (±2%) at the DUT
Drive level units: Vrms, Vp-p, dBm
Frequencies: 150, 300, 500, 600, 5k, 10k,
15k, 20k, 25k, 30k, 40k, 50k, 100k, 150k
and 200 kHz
DC bias current
Output current: 1 to 200 mA
Step size: 0.1 mA (1 to 20mA), 1mA (20 to 200 mA)
Basic accuracy: ±1% ±1 μA (1 to 20 mA),
±1% ±10μA (20 to 200 mA)
Compliance voltage: 22.5 V (into line side termination)
Power Supply
Input voltage: 115 V AC ±10% or 230 V AC
±10% (selectable)
Frequency: 50/60 Hz
Environmental
Installation category: II (in accordance with IEC664)
Temperature range: Storage -40°C to 70°C,
Operating 0°C to 40°C. Full accuracy 15°C to 35°C.
Relative humidity: up to 80% non-condensing
Pollution degree: 2 (mainly non-conductive)
Altitude: up to 2000 m
Safety
Complies with the requirements of EN61010-1
EMC
Immunity: EN61326-1
Emissions: EN55022 Class A
Mechanical
Height: 150 mm (6″)
Width: 440 mm (17 3/8″)
Height: 520 mm (20 1/2″)
Weight: 14 kg