供应风道型二氧化碳变送器
价格:电议
地区:上海
电 话:021 61340921
手 机:15950671722
传 真:021 61340921
品牌GE型号8041

T8041 CO2Duct Probe Sensor

Datasheet

 

TelaireÒVentostatÒT8041 CO2 Duct Probe Transmitter – Simple Installation!!

 

The T8041 is a CO2 transmitter designed to be installed in HVAC return air ducts. This product offers simplicity in design and installation. Available with analog 0-10V output only. Includes mounting hardware and installation instructions.

 

Specification

 

MeasurementRange:    0-2000 PPM factory calibrated

 

Duct Air Velocity:    0 to 1500 ft/min

 

Temp Dependence: 0.2% of full scale per ºC

 

Stability:                  <2% of full scale over the life of the sensor (15 years typical)

 

Accuracy:                        ±40 PPM+3% of reading @22ºC (72ºF) when compared with a factory certified reference.

 

Non-linearity:                  <1% of full scale @22ºC (72ºF)

 

Pressure Dependence:  0.13% of reading per mm of mercury

 

Calibration:                     Sensors will be calibrated at zero and span at the factory. Calibration in the field will not be required. Sensors will be shipped with ABC Logic™ turned on.*

 

Response Time:              3 minutes typical for a 90% step change at low duct speeds.

 

Sampling Rate:              Every 2 seconds, 25% duty cycle

 

Warm up time:                < 2minutes (Operational) 10 minutes to achieve maximum accuracy.

 

Operating Conditions:   Temperature: 0ºC to 50ºC (32ºF to 122ºF)

                                         Humidity:      0 to 95% Relative Humidity, non-condensing

 

Storage Conditions:       -20ºC to 70ºC (-40ºF to 158ºF)

 

Output:                            Analog 0 to 10 VDC (100 ohm output impedance)

 

Power Sup Reqmts:       18 to 30 VAC RMS, 50/60 Hz or 18 to 42 VDC, polarity protected.

 

Power Consumption:      Typical values (1.65 Watts Peak, 0.65 Watts Avg. @ 42 VDC)

*Note: Automatic Background Calibration or ABC Logic™ is a patented self- calibration technique utilized in applications where concentrations will drop to outside ambient conditions (Approximately 400 PPM) at least 3 times in a 14-day period, typically during unoccupied periods. Full accuracy is achieved after two weeks of operation.

 

Physical Requirements

 

Size:       Dimensions:

               Probe Length: 4.12”

               Probe Diam:   1.24”

 .

               Junction Box Depth:  1.6”

               Height:  3” square approximately

 

Color:  701 Black

 

Flammability Classification:UL 94V-5