·20Hz-1MHz has the test frequency of 8600 above
·The basic precision of 0.05% , resolution of 6 digit word
·Constant V or I check signal n
·20Vrms n options (options 001)
·Give 40Adc with Alilent 42841A feed
·Have list scanning to measure a function
Instrument of Agilent 4284A accurate LCR is the good in quality and cheap in price instrument that is used at component and material to measure. It passes the test means that provides accurate, high handling capacity to improve the quality of component. 20Hz measures frequency limits and admirable test signal widely to 1MHz, the most current test level is accorded with to be like IEC/MIL standard when making 4284A is testing cell (international Electrotechnical Committee or American military standard) , and below the working requirement that the job uses in imitate place. Receiving inspection still is in no matter studying development, production, quality,assuring, 4284A can satisfy all LCR to gauge a demand.

Technical index

The parameter that be measured | Z | - θ , | Y | - θ , r-X, g-B, c-D, q, ESR, g, rp, l-D, q, ESR, g, rp; deviation and % deviation
Measure circuit mode series connection and paralell connection
Span changeover is moved automatically with the hand
Spark in-house, exterior with bus line (HP-IB)
Defer time 0-60.00s is entered with 1ms pace
Measure terminal 4 end are right
Test cable length level: 0 with 1m; Take options 006 when: 0, 1, 2 with 4m
Accumulate minute of time: Short, medium wait and grow
Take average: 1-256 but programmed control
Test signal: 20Hz-1MHz ± 0.01%8610 optional choose frequency
Test signal way:   
Standard: Carry in the measurement of open circuit or short circuit respectively, is not be being measured on to choosing the voltage of one or voltaic process designing
Constant: Maintain be measured on the voltage of make choice of or electric current, and have nothing to do with impedance of parts of an apparatus and change
Test signal: N standard is constant
4284A 5mV~2V, 50 μ A-20mA 10mV-1V, 100 μ A-10mA
Options 001 5mV~2V, 50 μ A-200mA 10mV-10V, 100 μ A-100mA
 
Dc slants buy: Standard: 0V, 1.5V and 2V
Options: 0V- ± 40V 
Measure range of indication limits parameter
| Z | , r, x 0.01m Ω - 99.9999M Ω
| Y | , g, b 0.01nS-99.9999S
C HP
4284A:0.01fF-9.9999F 
L HP 4284A:0.01nH-99.9999kH
D 0.000001-9.99999
Q 0.01-99999.9
θ - 180 ° ~180.000 °
Δ % -999.999%~999.999%
 
Measure precision basically | Z | , c, l D
0.05% 0.0005
 
Complement is characteristic:   
Measure time: From touch say the word to arrive processor interfacial connection implement the end that go up is measured (EOM) the model of output measures time
Short 40ms
Medium 190ms
Grow 830ms
001 dc drift outputs options 100mAMax 
Monitor:   
LCD lattice shows: Indicate the value that be measured, control a setting, compare the limit and court decision, list scanning is expressed, check information and signal directive oneself
Correction function open a way / short circuit error is 0: Eliminate what cause by impedance of parasitism of stray of test clamping apparatus to measure an error
Receive load: Use already school parts of an apparatus is improved as reference measure precision
List scanning function can is opposite at most 10 frequency or process designing of test signal n. Can undertake second test or order check sheet, should install mount options 001 when, still can undertake dc bias voltage checks
Comparator
 10 storehouses room (Ten-bin) classification is used at measuring parameter. Input / output is used at measuring parameter 
Storehouse room computation: 0-999999
 
List scanning comparator: Tall / accord with / low decide every measurement point that output uses in list scanning watch
 
Other function:   
Memory / to load:
10 instruments setting can break memory easily to store by in-house blame / to load. 10 add settings still can be stored by calorie of memory / to load
All HP-IB instruments control a setting, be measured to be worth, compare the limit, list scanning is expressed and check a result oneself
Memory: Memory cache implement can store measure an outcome 128 times at most, output data via GPIB, ASCII and format of data of 64 binary systems

General technology index

± of 100/120/220V of power source requirement 10% , 240V
5%/-10% , 47-66Hz 
Power comsumption 200VA Max
Working temperature and humidity ℃ of 0 ° ~55, in ≤ of the relative humidity when 40 ℃ 95%
Dimension 42mm(is wide) *177(is tall) Mm*498mm(is long) (16.77 inches) * (6.97 inches) * (19.61 inches)
Weight:
Make an appointment with 16kg (35.2 pound)

Accessory:

·42841A slants buy electricity power supply
Slant buy impedance output: (5 ℃ of 23 ± ) ; 0.01A-20.0A
Basic impedance precision: It is when deserving to use with 4284A/4285A 1% (1kHz-1MHz)
Interface: Groovy, can take options by 4284A/ directly the 4285A control of 002
·HP 42842A/B slants buy electric current checks clamping apparatus
- slant to big dc buy electric current is measured, deserve to use with 4284A and 42841A:
42842A:20A Max
    42842B:40A Max
·42842C slants buy checks clamping apparatus:
Slant to big dc buy electric current is measured, use with 4285A and 42841A handle, 10A Max.
·42843A slants cable of buy electric current:
With 4284A, 42841A (2) , deserve to use with the 42842B that is used at the biggest electric current to be 40A
Main technique data:

·Data of technology of set of instrument of 4284A/4285A/4286A accurate LCR, p/n5963-5391E
·4284A technology data, p/n5963-5390E
·LCR instrument, impedance analyzer and guideline of choose and buy of test clamping apparatus, p/n 5950-1430E


If Your Exllency needs to know this equipment detailed circumstance, call to contact our sale engineer please, or send email to arrive Email: asks for product standards book

品牌/商标

HP

企业类型

贸易商

新旧程度

二手

原产地

美国