Type | DSF-88 (general) | DSF-88-H (high sensivity) | DSF-88 (low sensivity) | DSF-88-L (long distance) | DSF-710 -720 (variable) | DSF-88 -09 (general) | DSF-88-H -09-H (high sensivity) | DSF -G1 -G2 -GS | DSF -G3 | DSF -G4 | Rating voltage | AC110V, AC220V, A380V(50/60Hz) single, DC(order made) | 710-AC110V 720-AC220V | AC110V/220V(60Hz) multiple use, DC(order made) | Allowable voltage variable range | 85~110% of rating voltage | Voltage between electrode | AC10V | AC24V | AC10V | AC10V | AC24V | AC10V | Operating resistance | 10k? | 30k? | 2k? | 2.3k? | 82k? | 10k? | 30k? | 10k? | Return resistance | 13k? | 40k? | 6k? | 6.9k? | 118k? | 13k? | 40k? | 15k? | Max sense distance | below 500m | below 45m | below 60m | below 2km | below 80m | below 500m | below 45m | below 400m | Power consumption | about 1.6VA | about 1.8VA | about 2.0VA | about 2.3VA | about 4.5VA | Contact capacity | 250VAC, 5A | With- stand voltage | Electric circuit earth | AC 2000V/min | Between each circuits | AC 1500V/min | Ambient temperature | -10℃ ~ 60℃ | Ambient humidity | 45~80% RH | Response time | In operting, below 110ms, In return below 200ms | Mounting | DSF-09 : Desk type DSF-88, DSF-G : Socket type |
|
Type | Inherent resistance | Applied type | City water | 7 ~ 12k?.cm | DSF-09, DSF-88, DSF-720, DSF-G | Stream water | 5 ~ 17k?.cm | DSF-09-H(High sensivity), DSF-88-H(High sensivity), DSF-710,720, DSF-G | Well water | 7 ~ 15k?.cm | DSF-09, DSF-88, DSF-710,720, DSF-G(type) | Sea water | 0.04k?.cm | DSF-09-L(Low sensivity), |
|