总线连接器 | 6ES7972-0BA12-0XA0 6ES7972-0BB12-0XA | 6ES7972-0BA42-0XA0 6ES7972-0BB42-0XA0 | 6ES7972-0BA30-0XA0 1) |
---|
电缆引出线 | 90° 电缆引出线 | 35° 电缆引出线 | 30° 电缆引出线 | 用于 PLC |
|
|
| S7-200/-300/-400? | ?2) | ? | ? | S7-1200 with CM 1241, CM 1242-5; CM 1243-5 | ? |
|
| 带有 CP 5603 的 S7-mEC | ? | ? | ? | C7-633 DP, C7-634 DP, C7-635, C7-636 | ? | ? | ? | S5-115U 至 S5-155U | ? | ? | ? | I/O 设备 |
|
|
| ET 200M/ET 200B/ET 200L/ET 200S | ? | ? | ? | 编程设备 |
|
|
| PG 720/720C/PG 740/PG 760 |
| ? | ? | 接口 |
|
|
| IM 308-C | ? | ? | ? | CP 5431 FMS/DP | ? | ? | ? | CP 342-5/CP 343-5/ CP 443-5/IM 467 | ? | ? |
| CP 5511/CP 5512/CP 5711/CP 5603 | ? | ? | ? | CP 561x/CP 562x | ? | ? |
| SIMATIC OP |
|
|
| OLM/OBT | ? | ? |
| RS 485 中继器 | ? | ? |
| 诊断中继器 | ? | ? |
|
? 适用于以下应用 1) 不能将柔性总线电缆与此连接器结合使用, 1.5 Mbit/s 2) S7-400: 如果指定了 DP 接口,不能用于 MPI/DP 接口 如果指定了IFM2 接口,不能用于 IFM1 接口 总线连接器 | 6ES7972-0BA52-0XA0 6ES7972-0BB52-0XA0 | 6ES7972-0BA61-0XA0 6ES7972-0BB61-0XA0 | 6GK1500-0FC10 | 6GK1500-0EA02 |
---|
电缆引出线 | 90° 电缆引出线 | 35° 电缆引出线 | 180° 电缆引出线 | 180° 电缆引出线 | 用于 PLC |
|
|
|
| S7-200/-300/-400 | ? | ? |
|
| S7-1200 with CM 1241, CM 1242-5; CM 1243-5 | ? |
|
|
| 带有 CP 5603 的 S7-mEC | ? | ? | ? | ? | C7-633 DP, C7-634 DP, C7-635, C7-636 | ? | ? |
|
| S5-115U 至 S5-155U | ? | ? |
|
| I/O 设备 |
|
|
|
| ET 200M/ET 200B/ET 200L/ET 200S | ? | ? |
|
| 编程设备 |
|
|
|
| PG 720/720C/PG 740/PG 760 |
|
| ? | ? | 接口 |
|
|
|
| IM 308-C | ? | ? |
|
| CP 5431? FMS/DP | ? | ? |
|
| CP 342-5/CP 343-5/ CP 443-5/IM 467 | ? | ? |
|
| CP 5511/CP 5512/CP 5711/CP 5603 | ? | ? | ? | ? | CP 561x/CP 562x |
|
| ? | ? | SIMATIC OP |
|
| ? | ? | OLM/OBT | ? | ? | ? | ? | RS 485 中继器 | ? | ? |
|
| 诊断中继器 | ? | ? |
|
|
? 适用于以下应用 总线连接器 | 6ES7972-0BA70-0XA0 6ES7972-0BB70-0XA0 | | | |
---|
电缆引出线 | 90° 电缆引出线 |
|
|
| 用于 PLC |
|
|
|
| S7-200/-300/-400 | ? |
|
|
| S7-1200 with CM 1241, CM 1242-5; CM 1243-5 | ? |
|
|
| S7-1500 | ? |
|
|
| 带有 CP 5603 的 S7-mEC | ? |
|
|
| C7-633 DP, C7-634 DP, C7-635, C7-636 | ? |
|
|
| S5-115U 至 S5-155U | ? |
|
|
| I/O 设备 |
|
|
|
| ET 200M/ ET 200B/ ET 200L/ ET 200S, ET 200MP, ET 200SP | ? |
|
|
| 编程设备 |
|
|
|
| PG 720/720C/PG 740/PG 760 |
|
|
|
| 接口 |
|
|
|
| IM 308-C | ? |
|
|
| CP 5431? FMS/DP | ? |
|
|
| CP 342-5/CP 343-5/ CP 443-5/IM 467 | ? |
|
|
| CP 5511/CP 5512/CP 5711/CP 5603 | ? |
|
|
| CP 561x/CP 562x |
|
|
|
| SIMATIC OP |
|
|
|
| OLM/OBT | ? |
|
|
| RS 485 中继器 | ? |
|
|
| 诊断中继器 | ? |
|
|
|
技术规范Article number | 6ES7972-0BA12-0XA0 | 6ES7972-0BB12-0XA0 | 6ES7972-0BA42-0XA0 |
---|
Product description | PROFIBUS bus connector, RS485, screw, without PG socket, 90° | PROFIBUS bus connector, RS485, srew, with PG socket, 90° | PROFIBUS bus connector, RS485, screw, without PG socket, 35° |
---|
Suitability for use | For connecting PROFIBUS nodes to the PROFIBUS bus cable | For connecting PROFIBUS nodes to the PROFIBUS bus cable | For connecting PROFIBUS nodes to the PROFIBUS bus cable | Transmission rate |
|
|
| Transfer rate with PROFIBUS DP | 9.6 kbit/s ... 12 Mbit/s | 9.6 kbit/s ... 12 Mbit/s | 9.6 kbit/s ... 12 Mbit/s | Interfaces |
|
|
| Number of electrical connections |
|
|
| | 2 | 2 | 2 | | 1 | 1 | 1 | Type of electrical connection |
|
|
| | Screw | Screw | Screw | | 9-pin Sub-D connector | 9-pin Sub-D connector | 9-pin Sub-D connector | Type of electrical connection FastConnect |
| No | No | Mechanical data |
|
|
| Design of terminating resistor | Integrated resistor combination that can be selected with slide switch | Integrated resistor combination that can be selected with slide switch | Integrated resistor combination that can be selected with slide switch | Material of the enclosure | plastic | plastic | plastic | Locking mechanism design |
| Screw | Screw | Design, dimensions and weight |
|
|
| Type of cable outlet | 90 degree cable outlet | 90 degree cable outlet | 35 degree cable outlet | Width | 15.8 mm | 15.8 mm | 15.8 mm | Height | 64 mm | 64 mm | 54 mm | Depth | 35.6 mm | 35.6 mm | 39.5 mm | Net weight | 10 g | 10 g | 60 g | Permitted ambient conditions |
|
|
| Ambient temperature |
|
|
| |
| 0 °C | -25 ... +60 °C | | -40 ... +70 °C | -40 ... +70 °C | -40 ... +70 °C | | -40 ... +70 °C | -40 ... +70 °C | -40 ... +70 °C | Protection class IP | IP20 | IP20 | IP20 | Product properties, functions, components general |
|
|
| Product feature |
|
|
| | Yes | Yes | Yes | Product component |
|
|
| | No | Yes | No | | Yes | Yes | Yes | Standards, specifications, approvals |
|
|
| Certificate of suitability |
|
|
| | Yes | Yes | Yes | | Yes | Yes | Yes |
Article number | 6ES7972-0BB42-0XA0 | 6ES7972-0BA30-0XA0 | 6ES7972-0BA52-0XA0 |
---|
Product description | PROFIBUS bus connector, RS485, screw, mwith PG socket, 35° | PROFIBUS bus connector, RS485, Fast Connect, without PG socket, 30° | PROFIBUS bus connector, RS485, Fast Connect, without PG-socket, 90° |
---|
Suitability for use | For connecting PROFIBUS nodes to the PROFIBUS bus cable | For connecting PROFIBUS nodes to the PROFIBUS bus cable | For connecting PROFIBUS nodes to the PROFIBUS bus cable | Transmission rate |
|
|
| Transfer rate with PROFIBUS DP | 9.6 kbit/s ... 12 Mbit/s | 9.6 kbit/s ... 1.5 Mbit/s | 9.6 kbit/s ... 12 Mbit/s | Interfaces |
|
|
| Number of electrical connections |
|
|
| | 2 | 2 | 2 | | 1 | 1 | 1 | Type of electrical connection |
|
|
| | Screw | Integrated insulation displacement contacts for 2-core PB FC-installation cables | Integrated insulation displacement contacts for 2-core PB FC-installation cables | | 9-pin Sub-D connector | 9-pin Sub-D connector | 9-pin Sub-D connector | Type of electrical connection FastConnect | No | Yes | Yes | Mechanical data |
|
|
| Design of terminating resistor | Integrated resistor combination that can be selected with slide switch | no integrated terminating resistor | Integrated resistor combination that can be selected with slide switch | Material of the enclosure | plastic | plastic | plastic | Locking mechanism design | Screw |
| Screw | Design, dimensions and weight |
|
|
| Type of cable outlet | 35 degree cable outlet | 30 degree cable outlet | 90 degree cable outlet | Width | 15.8 mm | 15 mm | 15.8 mm | Height | 54 mm | 57.6 mm | 59 mm | Depth | 39.5 mm | 39.5 mm | 35.6 mm | Net weight | 67 g | 46 g | 10 g | Permitted ambient conditions |
|
|
| Ambient temperature |
|
|
| | -25 ... +60 °C |
| -25 ... +60 °C | | -40 ... +70 °C | -40 ... +70 °C | -40 ... +70 °C | | -40 ... +70 °C | -40 ... +70 °C | -40 ... +70 °C | Protection class IP | IP20 | IP20 | IP20 | Product properties, functions, components general |
|
|
| Product feature |
|
|
| | Yes | Yes | Yes | Product component |
|
|
| | Yes | No | No | | Yes | Yes | Yes | Standards, specifications, approvals |
|
|
| Certificate of suitability |
|
|
| | Yes | Yes | Yes | | Yes | Yes | Yes |
Article number | 6ES7972-0BB52-0XA0 | 6ES7972-0BA61-0XA0 | 6ES7972-0BB61-0XA0 |
---|
Product description | PROFIBUS bus connector, RS485, Fast Connect, with PG socket, 90° | PROFIBUS bus connector, RS485, Fast Connect, without PG socket, 35° | PROFIBUS bus connector, RS485, Fast Connect, with PG socket, 35° |
---|
Suitability for use | For connecting PROFIBUS nodes to the PROFIBUS bus cable | For connecting PROFIBUS nodes to the PROFIBUS bus cable | For connecting PROFIBUS nodes to the PROFIBUS bus cable | Transmission rate |
|
|
| Transfer rate with PROFIBUS DP | 9.6 kbit/s ... 12 Mbit/s | 9.6 kbit/s ... 12 Mbit/s | 9.6 kbit/s ... 12 Mbit/s | Interfaces |
|
|
| Number of electrical connections |
|
|
| | 2 | 2 | 2 | | 1 | 1 | 1 | Type of electrical connection |
|
|
| | Integrated insulation displacement contacts for 2-core PB FC-installation cables | Integrated insulation displacement contacts for 2-core PB FC-installation cables | Integrated insulation displacement contacts for 2-core PB FC-installation cables | | 9-pin Sub-D connector | 9-pin Sub-D connector | 9-pin Sub-D connector | Type of electrical connection FastConnect | Yes | Yes | Yes | Mechanical data |
|
|
| Design of terminating resistor | Integrated resistor combination that can be selected with slide switch | Integrated resistor combination that can be selected with slide switch | Integrated resistor combination that can be selected with slide switch | Material of the enclosure | plastic | plastic | plastic | Locking mechanism design | Screw |
|
| Design, dimensions and weight |
|
|
| Type of cable outlet | 90 degree cable outlet | 35 degree cable outlet | 35 degree cable outlet | Width | 15.8 mm | 15.8 mm | 15.8 mm | Height | 59 mm | 54 mm | 54 mm | Depth | 35.6 mm | 39.5 mm | 39.5 mm | Net weight | 10 g | 29 g | 34 g | Permitted ambient conditions |
|
|
| Ambient temperature |
|
|
| | -25 ... +60 °C | -25 ... +60 °C | -25 ... +60 °C | | -40 ... +70 °C | -40 ... +70 °C | -40 ... +70 °C | | -40 ... +70 °C | -40 ... +70 °C | -40 ... +70 °C | Protection class IP | IP20 | IP20 | IP20 | Product properties, functions, components general |
|
|
| Product feature |
|
|
| | Yes | Yes | Yes | Product component |
|
|
| | Yes | No | Yes | | Yes | Yes | Yes | Standards, specifications, approvals |
|
|
| Certificate of suitability |
|
|
| | Yes | Yes | Yes | | Yes | Yes | Yes |
Article number | 6ES7972-0BA70-0XA0 | 6ES7972-0BB70-0XA0 | 6GK1500-0EA02 | 6GK1500-0FC10 |
---|
Product type designation |
|
| PROFIBUS bus connector RS 485 | PROFIBUS FC bus connector RS 485 |
---|
Product description | PROFIBUS bus connector, RS485, Fast Connect, without PG-socket, 90° | PROFIBUS bus connector, RS485, Fast Connect, with PG socket, 90° | Bus connector with axial cable outlet (180°) | Bus connector with axial cable outlet (180°) |
---|
Suitability for use | For connecting PROFIBUS nodes to the PROFIBUS bus cable | For connecting PROFIBUS nodes to the PROFIBUS bus cable | For connecting PROFIBUS nodes to the PROFIBUS bus cable | For connecting PROFIBUS nodes to the PROFIBUS bus cable | Transmission rate |
|
|
|
| Transfer rate with PROFIBUS |
|
| 9.6 kbit/s ... 12 Mbit/s | 9.6 kbit/s ... 12 Mbit/s | Transfer rate with PROFIBUS DP | 9.6 kbit/s ... 12 Mbit/s | 9.6 kbit/s ... 12 Mbit/s |
|
| Interfaces |
|
|
|
| Number of electrical connections |
|
|
|
| | 2 | 2 | 2 | 2 | | 1 | 1 | 1 | 1 | Type of electrical connection |
|
|
|
| | integrated insulation displacement contacts for 2-core PB FC-installation cables | Integrated insulation displacement contacts for 2-core PB FC-installation cables | Terminal blocks | Integrated insulation displacement contacts for 2-core PB FC installation cables | | 9-pin Sub-D connector | 9-pin Sub-D connector | Sub-D connector (9-pin) | Sub-D connector (9-pin) | Type of electrical connection FastConnect | Yes | Yes | No | Yes | Mechanical data |
|
|
|
| Design of terminating resistor | Integrated resistor combination that can be selected with slide switch. Disconnect function: When the resistor is connected, the outgoing bus is isolated | Integrated resistor combination that can be selected with slide switch | Integrated resistor combination that can be selected with slide switch. Disconnect function: When the resistor is connected, the outgoing bus is isolated. | Integrated resistor combination that can be selected with slide switch. Disconnect function: When the resistor is connected, the outgoing bus is isolated. | Material of the enclosure | plastic | plastic | metal | plastic | Locking mechanism design | Screw | Screw | Screw | Screw | Design, dimensions and weight |
|
|
|
| Type of cable outlet | 90 degree cable outlet | 90 degree cable outlet | 180° cable outlet | 180° cable outlet | Width | 15.8 mm | 15.8 mm | 15 mm | 16 mm | Height | 72 mm | 72 mm | 57 mm | 62 mm | Depth | 36.4 mm | 36.4 mm | 39 mm | 34.5 mm | Net weight | 34 g | 10 g | 100 g | 40 g | Permitted ambient conditions |
|
|
|
| Ambient temperature |
|
|
|
| | -25 ... +60 °C | -25 ... +60 °C | 0 ... 60 °C | -40 ... +70 °C | | -40 ... +70 °C | -40 ... +70 °C | -25 ... +80 °C | -25 ... +80 °C | | -40 ... +70 °C | -40 ... +70 °C | -25 ... +80 °C | -25 ... +80 °C | Relative humidity at 25 °C without condensation during operation maximum |
|
| 75 % | 75 % | Protection class IP | IP20 | IP20 | IP20 | IP20 | Product properties, functions, components general |
|
|
|
| Product feature |
|
|
|
| | Yes | Yes | Yes | Yes | Product component |
|
|
|
| | No | Yes | No | No | | Yes | Yes | Yes | Yes | Standards, specifications, approvals |
|
|
|
| Certificate of suitability |
|
|
|
| | Yes | Yes | Yes | Yes | | Yes | Yes | No | Yes | |
|
| No | Yes | |
|
| No | No |
|